Dometic DM2852 Refrigerator Instruction Manual

Manual Dometic DM2852 Refrigerator Instruction Manual

Dometic DM2852 Refrigerator Instruction Manual

5/5 (1👤)
📕 Manual PDF 📄 40 Pages
★Rate It★

How many stars do you give this manual?

Dometic DM2852 Refrigerator

Full Screen

Dometic DM2852 Refrigerator

Full Screen

Dometic DM2852 Refrigerator Instructions

Here we offer the Dometic DM2852 Refrigerator manual completely free and in English. We have cataloged this manual in the Refrigerator section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Dometic DM2852 Refrigerator, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5

Dometic DM2852 Refrigerator Specifications

Feature Specification
Appliance type Absorption RV refrigerator, 2-way (120 V AC / LP gas), with automatic energy selector
Optional version DM2852 with optional power vent fan
Total refrigerated volume 8 cu.ft
Certification ANSI Z21.19 • CSA 1.4 (Refrigerators using gas fuel)
Overall dimensions (H x W x D) 60-51/64 x 24-7/8 x 26-1/32 in (1544 x 632 x 661 mm)
Recess dimensions (H x W x D) 59-15/16 x 23-11/16 x 24 in (1522 x 602 x 610 mm)
Minimum ventilation height (roof vent and lower side vent) 63-3/4 in (1620 mm)
Minimum clearances to combustibles Top 0, sides 0, bottom 0, rear 0 in
Certified vent system kit Kit 4A: roof base 3103633.XXX or 3310893.XXX, roof cover 3103634.XXX or 3310894.XXX, lower side vent 3109350.XXX
Minimum vent opening dimension 1/4 in
Gas connection 3/8 in SAE (UNF 5/8 in-18) male flare at manual gas valve
LP gas operating pressure 11 in water column (supply must not exceed 11 in WC)
AC power supply 120 V AC, grounded three-prong plug, 2 ft free cord length
Recommended AC receptacle location To the left of the refrigerator, 6 in above the mounting floor
12 V DC requirement Required for controls only (not for cooling)
Minimum control voltage 9.6 V DC
DC wire size / maximum total conductor length 12 AWG / 27 ft (8 m)
AC heater 325 W, 120 V (part no. 3850644-42/2)
Fuses Control system 3 A, AC heater 5 A; power vent fan inline fuse 3 A (fan version)
Burner jet No. 58 (part no. 2007419-21/7)
Electrode gap 1/8 to 3/16 in (3-5 mm)
Ignition sequence Approx. 45 s attempts at two-minute intervals (three attempts in AUTO mode)
Temperature control Factory preset temperature setting
Control panel ON/OFF button, AUTO/GAS mode selector button, AUTO lamp, CHECK lamp
Climate control Standard, 12 V DC, switch beneath the top decoration panel
Door panel max. thickness 5/32 in (4 mm)
Upper door panel size (H x W) 401-403 x 524-527 mm (15-25/32 to 15-27/32 x 20-5/8 to 20-3/4 in)
Lower door panel size (H x W) 981-983 x 524-527 mm (38-5/8 to 38-11/16 x 20-5/8 to 20-3/4 in)
Securing screws 5 (2 front base, 2 top frame, 1 rear base), not included
Initial cool-down time Up to 4 hours
Corrosion protection Sodium chromate, less than 2 weight % of coolant
Warranty Limited 3 years parts and freight, 2 years labor
Manual reference 825129301 (French 825129351)

Dometic DM2852 Refrigerator Details

The Dometic DM2852 uses an absorption cooling system. Ammonia liquefies in the finned condenser coil at the top rear, then flows into the evaporator inside the freezer. There, circulating hydrogen gas makes it evaporate and produce cold. The evaporator tubing is sloped so the liquid ammonia moves down by gravity. Because of this, the refrigerator must be level whenever the vehicle is parked for several hours. If it isn't, ammonia can pool in the tubing and block circulation. Level enough to live in comfortably is level enough. While driving, the vehicle's motion keeps the ammonia moving.

In AUTO mode, the controls pick between 120 V AC and LP gas, and AC always has priority. If AC is lost, the unit switches to gas. When AC comes back, it switches back to AC. If the burner doesn't light, the CHECK lamp comes on. Press the ON/OFF button off and on again to start a new ignition sequence. On this model, the AUTO lamp is off when the unit is running on gas only. After tanks are refilled, you can purge air from the gas lines by switching the unit off and on three or four times.

The DM2852 has a limp mode. If the control can't read the temperature sensor, it runs the cooling unit continuously on whatever energy source is available. It keeps doing this until a new sensor is installed and the system is reset. The standard climate control heats the frame between the compartments. This evaporates the water droplets that form in hot, humid weather. It draws 12 V DC continuously, so turn it off when no charging source is available.

Installation must be done by qualified personnel. The floor must be solid and level, and carpet must be removed or covered with a full-size metal or wood panel. A wood strip across the top of the enclosure anchors the top frame. A sealing strip on the front frame keeps the combustion system sealed off from the living space. Any gap above the unit larger than 1-1/2 inches must be blocked so heat doesn't build up. The drain hose must not touch the boiler casing. Check the LP safety shutoff after connecting the gas, without connecting 120 V AC.

The doors accept optional decorative insert panels. To fit a panel, remove the decoration strip, slide the panel into the grooves and seat it in the bottom groove. The door swing can be reversed with dedicated hinge kits. Kits come in light brown or black, for right-to-left or left-to-right conversion. For long-term storage, an Airing Position Card holds the doors ajar to prevent odors. Wire shelves can be moved after you release their locks with a screwdriver.

For food storage, the coldest spots are under the cooling fins and at the bottom of the cabinet. The upper door shelves are the warmest. The freezer is not designed for deep freezing or quick freezing. Precooled meat keeps about three times longer in the freezer than in the fresh food compartment. To defrost, switch the unit off and leave the doors open. Never use sharp tools or hot air blowers, because they can damage the ammonia system or warp parts.

A qualified technician should do maintenance at least once a year. This covers the connections, the controls, the LP gas pressure and the flue baffle. The flue should be cleaned from the top with a flue brush. Soak the burner jet in wood alcohol and blow it out with compressed air, and never clean it with a wire. The warranty requires this yearly preventive maintenance at an authorized Dometic center. It also lists reference readings, such as a thermocouple output of 25 to 35 millivolts.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Dometic DM2852 Refrigerator, and we answer them below.


Can the Dometic DM2852 cool using 12 V DC?
No. The DM2852 is a 2-way model that cools on 120 V AC or LP gas. It still needs a continuous 12 V DC supply to run the electronic controls, which work down to 9.6 V DC.

What is the storage capacity of the DM2852?
The DM2852 has a total refrigerated volume of 8 cu.ft.

What cutout size is needed to install the DM2852?
The recess must be 59-15/16 in high, 23-11/16 in wide and 24 in deep (1522 x 602 x 610 mm).

Which vent kit is certified for this model?
Vent kit 4A: roof base 3103633.XXX or 3310893.XXX, roof cover 3103634.XXX or 3310894.XXX, and lower side vent 3109350.XXX. Replace XXX with the color code. The minimum ventilation height is 63-3/4 in (1620 mm).

Can I adjust the temperature on the DM2852?
No. The DM2852 has no temperature selector. It works to a factory preset temperature setting.

Why is the CHECK lamp on?
The controls couldn't light the burner in gas mode. Make sure the LP tanks aren't empty and the manual valves are open. Then press the ON/OFF button off and on again to start a new ignition sequence.

How long does the refrigerator take to cool when started for the first time?
The cooling cycle can need up to four hours of running time before the cooling unit is fully working.

What gas pressure does the DM2852 need?
The correct operating pressure is 11 inches water column. Measure it at the test port just ahead of the burner jet.

What fuses does the DM2852 use?
A 3 A fuse for the control system and a 5 A fuse for the AC heater. Units with the optional power vent fan also have a 3 A inline fuse for the fan.

What wire size should be used for the 12 V DC connection?
Use 12 AWG wire, with a maximum total conductor length of 27 ft (8 m). Observe polarity and never use the chassis as a conductor.

Can the door swing be reversed?
Yes, with a door reversing kit. Light brown kits are 2932750-08/2 (right-left) and 2932750-09/0 (left-right). Black kits are 2932750-11/6 (right-left) and 2932750-12/4 (left-right).

What is the climate control switch for?
It turns on a 12 V DC heater that evaporates water droplets on the frame between the freezer and fresh food compartments. The switch is beneath the top decoration panel.

What does the warranty cover?
Major components are covered for three years on parts and freight and two years on labor. The owner must have preventive maintenance done every year at an authorized Dometic service center.

Related product manuals