Here we offer the Dometic DM2662 Refrigerator manual completely free and in English. We have cataloged this manual in the Refrigerator section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Dometic DM2662 Refrigerator, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.
Product Images
Dometic DM2662 Refrigerator Specifications
| Feature | Specification |
|---|---|
| Product type | Absorption RV refrigerator (ammonia/hydrogen cooling system) |
| Energy sources | 2-way: 120 V AC and LP gas, with automatic energy selection |
| 12 V DC requirement | Continuous 12 V DC supply required for the controls and automatic energy system |
| Minimum control voltage | 9.6 V DC |
| Total refrigerated volume | 6 cu. ft. |
| Overall dimensions (H x W x D) | 54-21/32 x 24-7/8 x 26-1/32 in (1388 x 632 x 661 mm) |
| Recess dimensions (H x W x D) | 53-3/4 x 23-11/16 x 24 in (1365 x 602 x 610 mm) |
| Minimum ventilation height (roof vent to lower side vent) | 57-3/4 in (1465 mm) |
| Clearances to combustible materials | Top 0 in, Sides 0 in, Bottom 0 in, Rear 0 in |
| Certified vent system kit | Kit 4A: Roof Base 3103633.XXX or 3310893.XXX, Roof Cover 3103634.XXX or 3310894.XXX, Lower Side Vent 3109350.XXX |
| Certification | ANSI Z21.19 / CSA 1.4 (refrigerators using gas fuel) |
| Gas connection | 3/8 in SAE (UNF 5/8 in-18) male flare at manual gas valve |
| LP gas operating pressure | 11 in water column |
| AC heater | 325 W, 120 V (part no. 3850644-42/2) |
| Burner jet | No. 58 (part no. 2007419-21/7) |
| Fuses | Control system 3 A, AC heater 5 A |
| Power cord | Grounded three-prong plug, 2 ft free cord length |
| Recommended 120 V AC receptacle location | To the left of the refrigerator, 3 in above the mounting floor |
| 12 V DC wiring | 12 AWG, maximum total conductor length 27 ft (8 m) |
| Ignition sequence | Three attempts of approx. 45 seconds each, at two-minute intervals |
| Electrode gap | 1/8 to 3/16 in (3–5 mm) |
| Control panel | ON/OFF button, AUTO/GAS mode selector, temperature selector (COLD 1–5 COLDEST); AUTO, AC, GAS and CHECK lamps |
| Upper door panel dimensions | Height 401–403 mm (15-25/32 to 15-27/32 in), width 524–527 mm (20-5/8 to 20-3/4 in) |
| Lower door panel dimensions | Height 825–827 mm (32-1/2 to 32-9/16 in), width 524–527 mm (20-5/8 to 20-3/4 in) |
| Maximum door panel thickness | 5/32 in (4 mm) |
| Securing screws | 2 in front base, 2 in top frame, 1 in rear base (screws not included) |
| Initial cool-down time | Up to 4 hours at first startup |
| Corrosion inhibitor | Sodium chromate, less than 2% by weight of coolant |
| Warranty | Limited 3 years on parts and freight, 2 years on labor (major components) |
| Manual reference | 825129301 (French 825129351) |
Dometic DM2662 Refrigerator Details
The Dometic DM2662 is a two-door absorption refrigerator for recreational vehicles and mobile homes. It is meant for storing fresh and frozen food and for making ice. It has no compressor. Instead, heat from either a 120 V AC heater or an LP gas burner drives a sealed ammonia, hydrogen and water circuit. Ammonia condenses in the finned coil at the top rear, then evaporates inside the freezer section, which produces the cooling.
The automatic energy selector chooses between AC and gas. In AUTO mode, AC has priority. If shore power is lost, the control switches to LP gas, and it switches back to AC as soon as AC returns. Users can also lock the unit in GAS mode. If ignition fails, the CHECK lamp lights. To reset it, press the ON/OFF button off and then on again. The lamp stays on even if AC power becomes available again, until it is reset this way.
The DM2662 has a user-adjustable thermostat that controls both gas and electric operation. You do not need to reset it when the energy source changes. For faster ice, you can set the thermostat to its coldest position for a while. Set it back to normal once the ice has formed, or the cabinet may get too cold.
A standard 12 V DC climate control heats the metal frame between the freezer and fresh food compartments. This stops water droplets from forming in hot, humid weather. The switch is under the top decoration panel. It draws 12 V DC continuously while it is on, so turn it off when no charging source is available.
The control system has two limp modes. If the display module fails, the unit keeps running automatically at the middle temperature setting. If the temperature sensor fails, the cooling unit runs continuously on the selected energy source until the sensor is replaced and the system is reset.
Leveling is essential. If the parked vehicle is not level, liquid ammonia can collect in the evaporator tubing and block circulation. A floor that feels comfortably level to live on is enough. While the vehicle is moving, leveling does not matter.
For installation, a wood strip must run across the upper opening of the enclosure. A sealing strip on the front frame keeps the combustion system separate from the living space. Any gap of more than 1-1/2 in above the refrigerator should be blocked so heat does not get trapped there. Do not install the unit directly on carpeting.
The door hinges can be reversed with dedicated kits (black right-left 2932750-11/6, black left-right 2932750-12/4). Optional decorative door insert panels slide into grooves in the door frame. They are held in place by a decoration strip, which is either screwed or snapped in.
For maintenance, the vents and rear coils should be cleaned once or twice a year. A qualified technician should check the flue baffle, the burner and the LP gas pressure every year. The Airing Position Card (3850781-01) holds the doors ajar during storage. To defrost, use the drip tray and hot-water trays, and never use sharp tools or hot air blowers.
Frequently Asked Questions (FAQs)
Can't find the answer you need? Here are some frequently asked questions about the Dometic DM2662 Refrigerator, and we answer them below.