Here we offer the Honeywell HZ322 TrueZONE manual completely free and in English. We have cataloged this manual in the Control Zone Boards section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Honeywell HZ322 TrueZONE, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5

Honeywell HZ322 TrueZONE Specifications

Feature Specification
Model Numbers HZ322, HZ322K (Kit)
Input Voltage 18-30 VAC, 50/60 Hz
Transformer Requirement 40 VA or more
Current Draw (Zone Panel) 7.5 VA max (at 24 VAC)
Current Draw (THM4000R) 2 VA max (at 24 VAC)
Wiring Type 18- or 20-gauge solid (not stranded) wire
Humidity Rating 5% to 90% RH non-condensing
Shipping Temperature -20° to 150°F (-29° to 66°C)
Operating Temperature -40° to 165°F (-40° to 74°C)
Dimensions (W x H x D) 11.5 in (292 mm) x 8 in (203 mm) x 1.86 in (47 mm)
Emissions Compliance FCC Class B, part 15 requirements
System Control (Conventional) Gas, oil, or electric forced-air systems; up to 2 stages heat, 2 stages cool
System Control (Heat Pump) Single stage compressor with auxiliary heat; Two stage heat pumps (without auxiliary heat)
Number of Zones 2 or 3 forced-air zones
Thermostat Compatibility Wired thermostats; Wireless thermostats (with THM4000R adapter)
Max. Damper VA per Zone (100°F/38°C) 28.8 VA
Max. Damper VA per Zone (160°F/71°C) 16.8 VA

Honeywell HZ322 TrueZONE Details

The Honeywell HZ322 TrueZONE panel is engineered for professional installation, offering a robust and adaptable solution for residential and light commercial zoning. Its core function is to intelligently manage temperature across multiple areas, ensuring optimal comfort and energy efficiency. The intuitive digital display, designed with real language prompts, guides installers through a straightforward setup, simplifying initial configuration and reducing installation time.

One of the panel's notable features is its universal application across various HVAC systems. It seamlessly integrates with conventional thermostat wiring schemes, utilizing standard R W Y G C terminals. This broad compatibility extends to different heating and cooling setups, from multi-stage conventional systems to heat pumps with or without auxiliary heat. A dedicated checkout procedure further validates correct operation before job completion, enhancing reliability.

For efficient wiring, the HZ322 incorporates robust push terminals capable of accommodating up to two wires per connection. The panel also boasts innovative wire management solutions, allowing wires to be routed discreetly behind the unit or through integrated side channels. A wiring anchor with a cable tie ensures organized and secure connections, contributing to a cleaner and more professional installation.

The HZ322 provides precise control over two or three-wire dampers, supporting both power-open/power-closed and spring-open/power-closed logic. Multiple dampers can be wired in parallel for increased zone capacity, and a Secondary Damper Control Relay (SDCR) can be utilized when a zone's maximum VA rating is exceeded. This flexibility ensures that a wide array of damper types and configurations can be effectively managed.

Advanced functionalities include variable-speed fan control, which is particularly beneficial for cooling applications. When only a single zone calls for cooling, the HZ322 can lower the blower fan speed via the DS/BK terminal, minimizing bypass air and improving comfort. Integrated Discharge Air Temperature Sensor (DATS) support allows the panel to automatically down-stage equipment if the supply air approaches predefined high or low-temperature limits, protecting the HVAC system.

The panel's operational status is clearly communicated through common-sense LEDs, indicating active heating and cooling stages, fan operation, purge cycles, and emergency heat status. Additionally, zone-specific LEDs show damper positions (green for open, red for closed) and can blink amber to signal diagnostic issues such as damper VA overloads or short circuits in thermostats or dampers, aiding in quick troubleshooting.

Configuration flexibility is a cornerstone of the HZ322. Beyond basic system type and zone count, installers can access advanced settings to fine-tune operation. Options include controlling the heat fan (by HVAC or panel), setting a Stage 2 Timer, adjusting the Purge Timer, configuring purge fan and damper behavior, and modifying auto-changeover delays. It also allows for enabling and setting limits for DATS and optional wireless Outdoor Temperature (OT) sensors.

The HZ322 TrueZONE panel supports RedLINK wireless devices, requiring an optional THM4000R Wireless Adapter. This enables the use of RedLINK wireless thermostats, portable comfort controls, and outdoor air temperature sensors, providing expanded system flexibility and control. The panel maintains compatibility with a wide range of thermostats, though caution is advised when using power-stealing or phantom voltage models without a dedicated 'C' wire.

Mounting the panel is adaptable; it can be secured to a wall, stud, roof truss, or cold-air return. The panel's base serves as a convenient template for drilling mounting holes, simplifying installation near the HVAC equipment. This comprehensive design, from robust hardware to intelligent control features, makes the Honeywell HZ322 a powerful solution for modern zoned HVAC systems.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Honeywell HZ322 TrueZONE, and we answer them below.


What types of HVAC systems can the HZ322 TrueZONE panel control?
The HZ322 panel controls conventional gas, oil, or electric forced-air systems up to 2 stages heat and 2 stages cool. It also manages heat pump systems with a single-stage compressor and auxiliary heat, or two-stage heat pumps without auxiliary heat.

How many zones can the HZ322 TrueZONE panel manage?
The HZ322 TrueZONE panel is designed to control 2 or 3 forced-air zones, accommodating either wired or wireless thermostats (with the optional THM4000R wireless adapter).

What type of wiring is recommended for the HZ322?
For connecting the HZ322 TrueZONE panel, 18- or 20-gauge solid (not stranded) wire is recommended to ensure reliable connections.

Can I use wireless thermostats with the HZ322 TrueZONE?
Yes, the HZ322 is compatible with RedLINK wireless thermostats and other wireless devices when used with the THM4000R Wireless Adapter Module, which connects to the ABCD terminals on the zone panel.

What is the purpose of the Discharge Air Temperature Sensor (DATS)?
The DATS (C7735A1000) monitors the supply duct air temperature. It enables the panel to down-stage multistage equipment if the air temperature approaches predefined high or low limits, protecting the HVAC system.

How do I enter the configuration mode on the HZ322 TrueZONE panel?
To enter configuration, press the Mode button until the "Config" LED lights up. You can then navigate through settings using the Back, Next, and Adjust Setting (Left/Right arrow) buttons.

What do the blinking LEDs on the HZ322 panel signify?
Blinking LEDs indicate specific issues: "HEAT 1" blinking means DATS high limit reached; "HEAT 2" or "COOL 2" blinking means stage 2 is locked out (due to DATS or OT); "PURGE" blinking means DATS sensor has failed, or wires are shorted/open; "ZONE 1, 2, or 3" blinking indicates damper VA overload or a thermostat/damper short circuit.

Can I wire multiple dampers to a single zone?
Yes, multiple dampers can be wired in parallel to a single zone. If the combined VA draw of dampers exceeds the zone's maximum rating, a Slave Damper Control Relay (SDCR) can be used to add additional dampers.

What is the 'Purge Timer' setting for in the advanced configuration?
The Purge Timer setting (options: 2, 3.5, or 5 minutes) determines the number of minutes the panel will purge (run the fan) following a call for heating or cooling, ensuring optimal air distribution.

Is the HZ322 compatible with both conventional and heat pump thermostats?
Yes, the HZ322 is compatible with most standard thermostats, including those for conventional systems and heat pump systems. It supports specific configurations for heat pump thermostats using 'O' or 'B' for changeover.

What is the function of the DS/BK terminal on the HZ322?
The DS/BK terminal is used with variable-speed fan HVAC equipment. When only one zone calls for cooling, this terminal is energized to run the blower fan at a reduced speed, requiring less air bypass and improving dehumidification.

How is the HZ322 TrueZONE panel typically mounted?
The HZ322 panel can be mounted on a wall, stud, roof truss, or cold-air return, usually near the HVAC equipment. It can be mounted in any orientation, using two screws for a stud/truss or four for duct/drywall installations.

What is the warranty period for the Honeywell HZ322 TrueZONE panel?
The HZ322 TrueZONE panel, along with other Honeywell zoning products with a date code of 0501 or later (excluding replacement maintenance parts), carries a sixty (60) months warranty from the date of installation.