Drayton RTS1 Thermostat Instruction Manual

Manual Drayton RTS1 Thermostat Instruction Manual

Drayton RTS1 Thermostat Instruction Manual

5/5 (1👤)
📕 Manual PDF 📄 2 Pages
★Rate It★

How many stars do you give this manual?

Drayton RTS1 Thermostat

Full Screen

Drayton RTS1 Thermostat

Full Screen

Drayton RTS1 Thermostat Instructions

Here we offer the Drayton RTS1 Thermostat manual completely free and in English. We have cataloged this manual in the Thermostats section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Drayton RTS1 Thermostat, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Miniatura 1
Miniatura 2
Miniatura 3

Drayton RTS1 Thermostat Specifications

Feature Specification
Model RTS1 – Standard heating room thermostat
Part number 24001
Manufacturer Drayton (Schneider Electric)
Electrical supply 230V ac, 50Hz, fused 3A
Insulation Double insulated (no earth required)
Temperature setting range 10 °C to 30 °C
Switch type S.P.S.T. (single pole, single throw), live output
Switch rating 2(1)A 230V ac
Temperature sensor Electronic, with relay output
Control accuracy <0.6 °C at 4 °C/hour
Wiring terminals used N (neutral), L (live supply), 3 (call for heat)
Circuit fuse 3A
Isolation requirement Switch with at least 3 mm contact separation in all poles
Wiring type Fixed wiring only, to IET wiring regulations (BS7671)
Mounting Surface mounting or flush single conduit box
Fixing screws No 6 x 1" woodscrews (wall) or M3.5 x 14 screws (conduit box)
Recommended mounting height Approx. 1.5 m (5 ft) above floor
Dimensions 86 mm x 86 mm x 37 mm
Operating ambient temperature 0 °C to 40 °C
Storage temperature -20 °C to 55 °C
Operating humidity (non-condensing) 25% to 90%
Storage humidity (non-condensing) 15% to 95%
Ball pressure test 75 °C
Pollution degree 2
Energy class I = 1% (EU 811/2013, 812/2013, 813/2013, 814/2013)
Relevant directives 2014/35/EU LVD, 2014/30/EU EMC, 2011/65/EU RoHS, 2012/19/EU WEEE
Applied standards EN60730-1, EN60730-2-9
Setting adjustment Rotary control knob with range limiting stops and set point locking

Drayton RTS1 Thermostat Details

The Drayton RTS1 is the standard heating model in the RTS room thermostat range made by Drayton, part of Schneider Electric. It uses electronic sensing to control room temperature accurately, and a relay to switch the heating demand. The manual points out that because it is electronic, the relay only works when the unit is connected to a 230V mains supply. If the unit is tested without mains power, you won't hear a click and the call-for-heat contact stays open. This is normal and doesn't mean the unit is faulty.

Where you fit the thermostat affects its performance. Keep it out of direct sunlight and draughts. The best spot is an inside wall where the unit can sense the true room temperature, away from radiators and other appliances that give off heat. Heat from these sources would make the thermostat switch off the heating too early. A good location lets the unit control comfort reliably while avoiding wasted energy.

Installation starts by loosening the securing screws and taking off the wall-plate. For surface wiring, you can snap out the cable entry strip on the bottom edge of the wall-plate with pliers. Fit the wall-plate with its terminals at the top. Wire it to the schematic diagram, then plug the thermostat onto the plate and tighten the screws. Always isolate the mains supply before fitting the thermostat to the wall-plate or removing it.

The RTS1 uses only three terminals: live supply to L, neutral to N, and the call-for-heat output on terminal 3. The manual says the neutral connection to terminal N is essential, because the electronic circuit needs it to run. The unit is double insulated, so an earthing continuity terminal is provided only as a convenient place to join earth conductors. Check that the circuit fuse is rated at 3A before switching the mains back on.

To set the temperature, turn the control knob until the required value lines up with the setting mark. A mechanism under the knob can limit the setting range or lock a fixed set point, which is useful in rented homes, offices or public buildings. To adjust it, set the temperature you want, carefully pull off the knob, then lift and rotate the two limiting arms into the required notches. Refit the knob so the same temperature lines up with the mark.

The RTS1 can replace older ACL and Drayton room thermostats, such as the ACL TS142 and the Drayton Roomstat RT and RTE, as long as the load is no more than 2(1)A. The manual includes conversion tables that map the old terminals to the RTS terminals, and also lists equivalents from other brands, including Danfoss Randall, Honeywell, Potterton, Sunvic and Horstman. This makes retrofitting easier for installers.

At the end of its life, don't throw the RTS1 thermostat away with household waste. Recycle it at an electronic waste facility. For help, Drayton runs a technical helpline on 0333 6000 622 and an email address, customer.care@draytoncontrols.co.uk. More information is available at draytoncontrols.co.uk.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Drayton RTS1 Thermostat, and we answer them below.


Why doesn't my Drayton RTS1 click when I test it?
The RTS1 is an electronic thermostat with a relay output. The relay only works when the unit is connected to a 230V mains supply, so without mains power you won't hear a click and the call-for-heat contact stays open.

Does the RTS1 need a neutral connection?
Yes. The manual says a neutral connection to terminal N is essential, because the electronic circuit needs it to run.

Which terminals are used to wire the RTS1?
Connect the live supply to L, neutral to N, and the call-for-heat output to terminal 3.

What temperature range can the RTS1 be set to?
You can set the RTS1 anywhere from 10 °C to 30 °C using the control knob.

Does the RTS1 need an earth connection?
No. The unit is double insulated, so it doesn't need an earth. The earthing continuity terminal is only there as a convenient place to join earth conductors.

How do I limit or lock the temperature setting?
Set the temperature you want, carefully pull off the knob, then lift and rotate the two limiting arms into the required notches. Refit the knob so the same temperature lines up with the setting mark.

Where is the best place to install the thermostat?
Fit it on an inside wall about 1.5 m (5 ft) above the floor. Keep it out of direct sunlight and draughts, and away from radiators and other sources of heat.

What fuse rating should the circuit have?
The circuit fuse must be 3A. Your fixed wiring should also include an isolation switch with at least 3 mm contact separation in all poles.

Can the RTS1 replace my old ACL or Drayton thermostat?
Yes. It can replace older models such as the ACL TS142 and the Drayton RT and RTE, as long as the load is no more than 2(1)A 230V ac. The manual includes terminal conversion tables.

What is the part number of the Drayton RTS1?
The part number of the RTS1 SPST standard thermostat is 24001.

What are the dimensions of the RTS1?
The thermostat measures about 86 x 86 x 37 mm, and it can be mounted on the wall surface or on a single conduit box.

Related product manuals