Drayton LP111 Thermostat Instruction Manual
Drayton LP111 Thermostat
Drayton LP111 Thermostat
Drayton LP111 Thermostat
Drayton LP111 Thermostat Instructions
Here we offer the Drayton LP111 Thermostat manual completely free and in English. We have cataloged this manual in the Thermostats section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Drayton LP111 Thermostat, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.
Product Images
Drayton LP111 Thermostat Specifications
| Feature | Specification |
|---|---|
| Product type | Lifestyle single-channel 24-hour electronic timeswitch (controls heating OR hot water) |
| Product part number | LP111: 25477 / LP111Si: 25493 |
| Program type | 24-hour program, the same every day |
| Timed periods | Up to 3 per day (ON1/OFF1, ON2/OFF2, ON3/OFF3) |
| Operating modes | OFF, TIMED, ONCE, ON |
| Factory standard program | ON1 6.30am, OFF1 8.30am, ON2/OFF2 12.00pm (inactive), ON3 4.30pm, OFF3 10.30pm |
| Power supply | 230V a.c. +10% / -10%, 50Hz |
| Timeswitch rating | 2(1)A 230V a.c. |
| Output | Volt-free contacts (output depends on the supply to the common terminal) |
| Mains input fuse | 3A |
| Programming / timing resolution | 1 minute |
| Time adjustment steps | 1-minute steps; 10-minute steps when the – or + button is held down |
| Advance function | Moves to the next ON or OFF period (works only in TIMED or ONCE mode) |
| Boost function | Extra 1, 2 or 3 hours, shown on the LCD |
| Holiday mode | Switches the system off for a set number of days, then returns to normal operation |
| Clock | Pre-set at the factory, with automatic British Summer Time changeover (DLS on/off) |
| Display | Backlit LCD and a red indicator light that shows when the output is on |
| Without mains power | Display goes blank; the time and program times are kept |
| Operating temperature | 0 °C to 45 °C (installation data); 0 °C to 50 °C (datasheet) |
| Storage temperature | -20 °C to 50 °C |
| Ambient humidity | Operating 25% to 90%; storage 15% to 95% (non-condensing) |
| Pollution degree | 2 |
| Software class | 2 (installation instructions); A (datasheet) |
| Ball pressure test temperature | 75 °C |
| Rated impulse voltage | 2.5kV |
| Insulation | Double insulated, so no earth is needed; an earth continuity (loop) terminal is provided |
| Terminals | N, L, 1 (Common), 2 (On), 3 (Off), 4 (Spare) |
| Wiring | Fixed wiring only, to current IEE/IET wiring regulations (BS7671) |
| Mounting | Industry-standard wall-plate; flat wall (No. 6 x 1" / 25mm woodscrews) or flush single conduit box UA1 (BS4662) with M3.5 x 14 bolts. Do not use a surface-mounting box. |
| Recommended mounting height | 1.4m above floor level |
| Required clearance | 70mm to the right and 25mm above the wall-plate, plus access to the securing screws underneath |
| Outline dimensions (drawing) | 148mm x 93mm |
| Building regulations | Part L compliant (Part J in Scotland) |
| Directives | 2014/30/EU EMC, 2014/35/EU Low Voltage, 2006/66/EC Batteries, 2011/65/EU RoHS |
| Applied standards | EN60730-1; EN60730-2-7 |
| Maintenance | Must be maintained by a qualified electrician or heating engineer |
| Manual reference | 06490033001 ISS L |
| Technical helpline | 0333 7000 622 / customer.care@draytoncontrols.co.uk |
Drayton LP111 Thermostat Details
Although it is often called a thermostat, the Drayton LP111 is a timeswitch from the Lifestyle range. It switches one circuit, either heating or hot water, on and off at times you choose. Drayton suggests it where simple time control is enough, especially with combination boilers or extra zones. Its large buttons and simple layout have made it popular with elderly users. Remember that the room thermostat still has the final say. If the thermostat has switched off, the heating will not run, even during an ON period.
The factory program gives two active periods, morning and evening. The middle period is inactive because ON2 and OFF2 are both set to 12.00pm. To use it, set two different times. To change the program, press SET? until SET PROG? appears, then press YES. Adjust each time with – and +, and press SET? to move to the next one. You can also press SET? to leave a time unchanged. After OFF3, one more press of SET? returns the unit to normal operation.
Times must be entered in order: ON1, OFF1, ON2, OFF2, ON3, OFF3. If they get out of order, the display flashes a warning. ON1 cannot be the last time before midnight. OFF3 can fall after midnight, as long as it is no more than 23 hours 59 minutes after ON1. To clear your changes and go back to the factory program, press SET and + together.
The Advance/Boost button on the front gives temporary control without changing the program. Pressing Advance shows ADV and moves the output to the next state. If the system is off, it turns on until the end of the next period. If it is on, it turns off until the next ON time. Pressing and holding Boost shows BST and adds one hour. Press it again for two or three hours. Press it once more to cancel.
The SELECT button under the flap chooses one of four modes. OFF keeps the system off and ON keeps it on. TIMED follows the three daily periods. ONCE runs one long period from ON1 to OFF3. Changing the mode never deletes your saved times, so you can return to them at any time by selecting TIMED.
Holiday mode is useful when the house will be empty. Press SET? three times to reach SET H'DAY?, press YES, then set the number of days with + and –. The unit counts each pass through midnight as one day. For example, if you leave on Saturday morning and want heating again on Tuesday morning, set three days. The display shows H'DAY until normal operation resumes.
The clock is set at the factory, but you can set it yourself through SET CLOCK?. Set the hour (check AM or PM), then the minutes. Under SET DATE?, set the year, month and day. The day of the week is worked out from the date, so if the weekday shows wrong, correct the date. The last step turns automatic Daylight Saving (DLS) on or off.
When replacing an old timeswitch, the LP111 can usually be plugged into the existing wall-plate, after checking the terminal comparison chart. Because the contacts are volt-free, Terminal 1 must be supplied, either by a link from L or by a separate supply with a 3A fuse. Always switch off the mains before removing the unit, and never fit it to a live wall-plate. The LP111Si version adds a boiler service reminder. Thirty days before the service is due, it flashes the display and sounds an alarm. If the service is still not done, it lowers heating comfort until a separate reset unit is used.
Frequently Asked Questions (FAQs)
Can't find the answer you need? Here are some frequently asked questions about the Drayton LP111 Thermostat, and we answer them below.