Here we offer the Dometic DM2862 Refrigerator manual completely free and in English. We have cataloged this manual in the Refrigerator section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Dometic DM2862 Refrigerator, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Miniatura 1
Miniatura 2
Miniatura 3

Dometic DM2862 Refrigerator Specifications

Feature Specification
Model Dometic DM2862 (also available with optional ventilator fan)
Refrigerator Type Absorption refrigerator for RVs and mobile homes, 2-way (120 V AC / LP gas)
Total Refrigerated Volume 8 cu.ft
Overall Dimensions (H x W x D) 60-51/64 x 24-7/8 x 26-1/32 in (1544 x 632 x 661 mm)
Recess Dimensions (H x W x D) 59-15/16 x 23-11/16 x 24 in (1522 x 602 x 610 mm)
Extra Depth with Optional Fan Add 1 in (25 mm)
Minimum Ventilation Height (roof vent and lower side vent) 63-3/4 in (1620 mm)
Certified Vent System Kit Kit 4A: Roof Base 3103633.XXX or 3310893.XXX, Roof Cover 3103634.XXX or 3310894.XXX, Lower Side Vent 3109350.XXX
Minimum Clearances to Combustibles Top 0 in, Sides 0 in, Bottom 0 in, Rear 0 in
Certification ANSI Z21.19 / CSA 1.4 (refrigerators using gas fuel)
Gas Connection 3/8 in SAE (UNF 5/8 in-18) male flare at manual gas valve
LP Gas Operating Pressure 11 inches water column (maximum supply pressure)
Burner Jet No. 58 (part no. 2007419-21/7)
AC Heater 325 W, 120 V (part no. 3850644-42/2)
AC Power Supply 120 V AC, grounded three-prong plug, 2 ft free cord length
AC Receptacle Location Left of refrigerator, 3 in above mounting floor
12 V DC Supply Continuous 12 V DC required for controls and automatic energy selection
Minimum Control Voltage 9.6 V DC
DC Wiring 12 AWG, maximum total conductor length 27 ft (8 m)
Fuses Control system 3 A, AC heater 5 A, power vent fan inline fuse 3 A (fan versions)
Control Panel ON/OFF, AUTO/GAS selector, temperature selector with 5 indicator lamps, AUTO, AC, GAS and CHECK lamps
Thermostat Adjustable, controls both gas and electric operation
Climate Control Standard 12 V DC, switch beneath top decoration panel
Door Panel Size, Upper (H x W) 401–403 x 524–527 mm (15-25/32–15-27/32 x 20-5/8–20-3/4 in)
Door Panel Size, Lower (H x W) 981–983 x 524–527 mm (38-5/8–38-11/16 x 20-5/8–20-3/4 in)
Maximum Door Panel Thickness 5/32 in (4 mm)
Electrode Gap 1/8 to 3/16 in (3–5 mm)
Refrigerant System Ammonia, hydrogen, water; sodium chromate corrosion protection (less than 2 weight %)
Securing Screws 2 through front base, 2 in top frame, 1 in rear base (not included)
Diagnostic Reference Values Thermistor 7,000–10,000 ohms at 32°F; DC 9.5–15 V; AC 120 V ±10%; thermocouple 25–35 mV
Key Spare Parts Burner 2930697-07/9, Electrode 2932781-01/2, Baffle 2932667-04/7, Airing position card 3850781-01, Lamp cover 2932106-01/2
Door Reversing Kits (black) Right-left 2932750-11/6, Left-right 2932750-12/4
Warranty Limited 3 years parts and freight, 2 years labor

Dometic DM2862 Refrigerator Details

The Dometic DM2862 is an absorption refrigerator. It has no compressor, so it runs silently. Ammonia condenses in the finned coil at the top rear of the unit, then flows into the freezer evaporator, where circulating hydrogen makes it evaporate and produces the cooling. Because the system depends on gravity, the unit must be level whenever the vehicle is parked for several hours. On the road, the vehicle's movement keeps the ammonia from pooling. When you start the unit for the first time, the cooling cycle may need up to four hours to become fully operational.

The automatic energy selector picks the best power source available. In AUTO mode, 120 V AC has priority, and the system switches to LP gas when shore power is lost. If the burner does not light, the controls make three ignition attempts of about 45 seconds each, two minutes apart, and then turn on the CHECK lamp. To reset, press ON/OFF off and then on again. If there is air in the gas lines after refilling the tanks, repeat this power cycle three or four times.

The controls also have limp modes. If the display module fails, the refrigerator keeps running automatically with the temperature held at the middle setting. If the temperature sensor fails, the cooling unit runs continuously on the selected energy source until the sensor is replaced. The built-in climate control evaporates condensation that forms on the frame between the compartments in hot, humid weather. It draws 12 V DC continuously, so turn it off when no charging source is available.

Installation must be done by qualified personnel. The unit should sit on a solid, level floor and must never be placed directly on carpet. A wood strip across the upper opening of the enclosure anchors the top frame. A sealing strip on the front frame keeps the combustion system separate from the living space. Any gap of more than 1-1/2 inches above the unit should be blocked to prevent heat buildup. Run the drain hose through the floor so that it does not touch the boiler casing.

For food storage, the coldest areas are under the cooling fins and at the bottom of the cabinet. The upper door shelves are the warmest. The freezer is not meant for quick freezing. Precool meat and fish before putting them in, and keep ice cream at the bottom of the aluminum liner. Cover foods to keep them from drying out or sharing odors, and avoid overpacking the shelves so that air can circulate. Setting the thermostat to its highest position makes ice faster.

For defrosting, turn the unit off, empty it, and place the drip tray under the evaporator. Never use sharp tools or hot air blowers. Clean the interior with a mild soda solution. For storage, the included Airing Position Card holds the doors ajar. A technician should inspect the flue, burner, gas pressure and controls every year, which is also required to keep the warranty valid. The door swing can be reversed with a hinge kit, and optional decorative insert panels can be fitted.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Dometic DM2862 Refrigerator, and we answer them below.


What energy sources does the Dometic DM2862 use?
The DM2862 is a 2-way model that runs on 120 V AC or LP gas. It also needs a continuous 12 V DC supply to run its electronic controls and automatic energy selector.

What is the storage capacity of the DM2862?
Its total refrigerated volume is 8 cubic feet.

What recess size is needed to install the DM2862?
The cutout must be 59-15/16 in high, 23-11/16 in wide and 24 in deep (1522 x 602 x 610 mm). Add 1 in (25 mm) of depth for versions with the optional ventilator fan.

Why does my refrigerator take so long to cool the first time?
Absorption cooling systems need time to start circulating. On first start-up, the cooling cycle may take up to four hours to become fully operational.

What does the CHECK lamp mean?
It means the controls could not light the gas burner after three ignition attempts. Press the ON/OFF button off and then on again to restart ignition. Also check that the gas tanks are not empty and that the valves are open.

Why is it important to keep the refrigerator level?
If the parked unit is not level, liquid ammonia can collect in the evaporator tubing and block circulation, which causes a loss of cooling. Level the vehicle whenever it is parked for several hours.

What is the climate control used for?
It evaporates water droplets that form on the frame between the freezer and fresh food compartments in hot, humid weather. The switch is under the top decoration panel. Turn it off when no 12 V charging source is available.

What gas pressure does the DM2862 require?
The correct LP gas operating pressure is 11 inches of water column, measured at the test port just ahead of the burner jet.

Which fuses does the DM2862 use?
The control system uses a 3 A fuse and the AC heater uses a 5 A fuse. Versions with the optional fan also have a 3 A inline fuse for the power vent fan.

Can I reverse the door swing?
Yes. Use the black door reversing kit: part no. 2932750-11/6 for right-to-left or part no. 2932750-12/4 for left-to-right.

How should I defrost the refrigerator?
Turn the unit off, empty it, leave the doors open and place the drip tray under the evaporator. Never use sharp tools or hot air blowers, because they can damage the ammonia system or warp parts.

What maintenance is required to keep the warranty valid?
An authorized Dometic service center must perform yearly preventive maintenance, including inspection, cleaning and full diagnostics of the electronics, burner, wiring and cooling unit. Keep the receipts as proof.

What warranty does the DM2862 have?
It has a limited three-year warranty covering parts and freight on major components, and two years of labor from the date of purchase by the original purchaser.