Honeywell HE360 Humidifier Instruction Manual
Honeywell HE360 Humidifier
Honeywell HE360 Humidifier
Honeywell HE360 Humidifier Instructions
Here we offer the Honeywell HE360 Humidifier manual completely free and in English. We have cataloged this manual in the Humidifiers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Honeywell HE360 Humidifier, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.
Product Images
Honeywell HE360 Humidifier Specifications
| Feature | Specification |
|---|---|
| Model Numbers | HE360A1075, HE360D1075 |
| Humidifier Type | Whole-house, duct-mounted evaporative (flow-through pad) humidifier |
| Electrical Input | 120 Vac, 60 Hz, 0.7 A |
| Control Voltage | 24 Vac (constant), R and C terminals on the humidistat |
| Ambient Operating Temperature | 32°F to 160°F (0°C to 71°C) |
| Maximum Supply Plenum Static Pressure | 0.4 in. wc |
| Maximum Water Pressure | 124 psi |
| Water Flow Rate (Running) | 3.5 gal/hr (13 liters/hr) |
| Compatible Water | Hard or soft water, hot or cold water |
| Feed Water Tubing | 1/4 in. (6.35 mm) OD, plastic or copper |
| Drain Tubing | 1/2 in. (12.7 mm) ID |
| Control Wiring | 18 gauge, two-strand thermostat wire |
| Mounting Location | Supply (warm air) plenum, at least 3 in. (78 mm) above the furnace body |
| Included Humidistat | H6062 Humidistat (outdoor sensor capable, Humidity Boost display) |
| Humidistat Duct Placement | Return duct, at least 8 in. (203 mm) upstream from the humidifier |
| Humidistat Duct Tube Hole | 1/2 in. (12.7 mm) |
| Airflow Proving Device | Pressure switch (included) |
| Pressure Switch Temperature Rating | -40°F to 190°F (-40°C to 88°C) |
| Pressure Tap Holes | 3/4 in. (19 mm) diameter, within 10 ft (3 m) of the switch |
| Water Distribution | PerfectFlow™ water distribution tray |
| Included Hardware | 4 wire nuts, 18 No. 8 sheet metal screws, drain tube clamp, 6 feed tube clamps, 2 brass inserts, 2 plastic compression rings |
| Mounting Template | Form number 69-2641 (included) |
| Installation Kit Contents (Kit 69-1572) | 20 ft (6.2 m) thermostat wire, 20 ft (6.2 m) feed tubing, 10 ft (3.1 m) drain tubing, S688A sail switch, duct tape, mounting hardware |
| Sail Switch Minimum Duct Size (Kit) | 12 in. (305 mm) deep x 8 in. (203 mm) wide |
| Maintenance Interval | Every 1 to 3 months, depending on water quality |
| Warranty | Limited one-year (excluding battery) |
| Manufacturer | Resideo Technologies, Inc. (Honeywell Home trademark under license) |
Honeywell HE360 Humidifier Details
The Honeywell HE360 Humidifier is a whole-house unit that mounts on the supply plenum and adds moisture to the warm air from the furnace. Water is spread evenly over a pad. Warm, dry air passes through the pad, picks up the evaporated water and carries it through the home. Because humidified air feels warmer, you can often lower your thermostat heating setpoint and save on fuel. The manual also notes that it helps relieve dry skin, scratchy throats and irritated nasal passages, cuts down on static shocks and protects wood furniture.
Installation starts with a level line drawn on the plenum, since a level unit gives the best performance. The installer tapes the supplied template in place, cuts a rectangular opening and removes the cover and pad assembly. Securing clips and plastic tabs sit on the upper sheet metal edge of the opening, and sheet metal screws hold the housing in place. Do not mount the unit on the furnace body or anywhere that could damage the air conditioner A-coil. Leave enough clearance in front of and above the unit to remove the cover easily.
For plumbing, install a code-compliant shut-off valve. Never tap a line connected to an air conditioner or a gas line. Use plastic (Delrin) compression rings with plastic tubing and copper rings only with copper tubing. Discard the copper ring supplied with the valve when using plastic tubing. Tighten the compression nut only moderately to prevent leaks. Route the drain line on a continuous downward slope to a floor drain. If no floor drain is available, Resideo recommends a drum or disk humidifier instead.
The pressure switch mounts vertically with its pressure connectors facing down. Supply duct tubing goes to the + port and return duct tubing goes to the – port. You can use either port alone or both together. The H6062 humidistat can mount on the return duct, where wiring is easiest, or on a living space wall like a thermostat. Wiring follows the diagram in the humidifier manual, not the one packed with the humidistat. The red and white conductors can be swapped, and the NC terminal on the pressure switch is not used.
The separate HE360 Installation Kit uses an S688A sail switch and an H8908 humidity control. The sail switch has counterbalancing springs. Keep the "Down" spring for downward airflow and the "Up" spring for upward airflow, and remove both for horizontal ducts. The sail switch should go in the cold air return, because supply duct heat shortens the sail's life. The kit's self-piercing saddle valve should be installed with its handle pointing toward the ceiling so debris does not clog the solenoid's inline filter.
For daily use, an outdoor sensor lets the H6062 adjust humidity automatically and limit window condensation. Without the sensor, use the manual's chart: setting 15 at -20°F, rising to 40 above 20°F. Cooking, showering and drying clothes can push humidity too high. If these activities continue for several hours, turn the control to its lowest setting. Maintenance means cleaning mineral deposits from the tray, nozzle and drain hose, and replacing the pad with its marked end facing up. Never oil any part of the humidifier.
Frequently Asked Questions (FAQs)
Can't find the answer you need? Here are some frequently asked questions about the Honeywell HE360 Humidifier, and we answer them below.