Ideal MAX Logic Heat H30 Boiler Instruction Manual
Ideal MAX Logic Heat H30 Boiler
Ideal MAX Logic Heat H30 Boiler
Ideal MAX Logic Heat H30 Boiler
Ideal MAX Logic Heat H30 Boiler
Ideal MAX Logic Heat H30 Instructions
Here we offer the Ideal MAX Logic Heat H30 Boiler manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Ideal MAX Logic Heat H30 Boiler, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.
Product Images
Ideal MAX Logic Heat H30 Boiler Specifications
| Feature | Specification |
|---|---|
| Boiler Type | Wall-mounted, heat only, condensing gas boiler with fan-assisted combustion |
| G.C. Appliance No. (Benchmark No.) | 41-860-29 |
| Gas Supply | 2H - G20 - 20 mbar (Natural Gas); LPG conversion available |
| Rated Heat Output | 30 kW |
| Boiler Input (Net CV) Min / Max | 6.1 kW / 30.4 kW |
| Boiler Input (Gross CV) Min / Max | 6.7 kW / 33.7 kW |
| Gas Consumption Min / Max | 0.623 m³/h / 3.136 m³/h |
| Output Non-Condensing (70ºC Mean Water Temp.) | 6.1 - 30.3 kW |
| Output Condensing (40ºC Mean Water Temp.) | 6.4 - 31.0 kW |
| Nominal Heat Output Full Load (P4) / Part Load (P1) | 30.3 kW / 9.8 kW |
| Central Heating Flow Temperature Range | 30ºC - 80ºC |
| Seasonal Space Heating Energy Efficiency (ηs) | 93% |
| Seasonal Space Heating Efficiency Class | A |
| Useful Efficiency Full Load (η4) / Part Load (η1) | 89.6% / 98.2% |
| SEDBUK 2005 / SEDBUK 2009/2012 | 91.1% / 89.6% |
| NOx Classification | Class 6 (24 mg/kWh gross) |
| Annual Energy Consumption (QHE) | 93 GJ |
| Sound Power Level, Indoors | 50 dB (LWA); 49 dB(A) |
| CO2 Content (± 0.7) | Max CH 9.7% / Min CH 8.8% |
| Average Flue Temperature - Mass Flow Rate | 69ºC - 13 g/s |
| Injector Size | 4.65 mm |
| Gas Supply Connection | 15 mm copper compression |
| Flow / Return Connections | 22 mm copper compression (top connection) |
| Flue Terminal Diameter | 100 mm |
| Maximum Horizontal Flue Length | 8.0 m (Installation manual); 9 m (Technical specification sheet) |
| Maximum Vertical Flue Length | 7.5 m |
| Flue Elbow Equivalent Resistance | 45º elbow: 0.6 m; 90º elbow: 1.0 m |
| Appliance Flue Types | C13, C33, C53 (room sealed) |
| Maximum Working Pressure (Sealed Systems) | 2.5 bar (36.3 psi) |
| Water Content (Central Heating) | 1.2 litres (0.26 gal) |
| Heat Exchanger Material | Cast aluminium |
| Electrical Supply | 230 V ~ 50 Hz |
| Power Consumption | 52 W |
| Auxiliary Electricity Full Load / Part Load / Standby | 0.052 kW / 0.012 kW / 0.001 kW |
| Fuse Rating | External: 3 A; Internal: T4A HRC L250V |
| Ingress Protection | IP20 |
| Casing Dimensions (H x W x D) | 700 x 395 x 278 mm |
| Packaged Weight / Lift Weight | 27.0 kg / 21.9 kg |
| Servicing Clearances | 165 mm above, 100 mm below, 2.5 mm sides, 450 mm front |
| Condensate Trap | Siphonic, 75 mm seal; outlet for 21.5 mm overflow pipe |
| Maximum / Minimum Rate Fan Speed | 6800 rpm / 1400 rpm |
| Frost Protection | Activates when boiler water falls below 5ºC |
| Warranty | 10 years parts and labour (when registered within 30 days) |
Ideal MAX Logic Heat H30 Boiler Details
The Ideal MAX Logic Heat H30 is the most powerful model in the Logic Max Heat2 range. It is a heat only boiler, so it heats radiators and a separate hot water cylinder. It lights with a full sequence automatic spark, and a single electrode handles both spark ignition and flame detection. It works on fully pumped open vented or sealed systems, but it cannot be used on gravity circulation systems. It has no built-in pump, so an external system pump must be fitted on the flow side.
The boiler is controlled through a large colour display, four hot keys and a central heating temperature knob. Pressing Mode switches between Off, Ready and On. When an outside sensor is fitted, Summer and Winter modes are also available. The display shows up to three scrolling messages, and a leaf symbol marks the most economical knob setting, where the boiler condenses most efficiently. Ideal notes that turning the room thermostat down by 1ºC can cut gas use by up to 10%.
Intelligent Load Optimisation stops the boiler switching on and off too often. If the flow temperature goes 4ºC above the central heating target, the burner shuts off. When it relights, it drops to minimum rate over 60 seconds and stays there for 10 minutes. The 1:1 gas valve made by Honeywell lets the boiler reach full output at inlet pressures as low as 14 mbar.
The boiler works with OpenTherm controls, the Ideal weather compensation sensor (part 216119) and the Halo range. That includes Halo RF, Halo Wi-Fi, Halo Lite and a 2-Zone extension kit. The Halo wiring centre can reuse an existing switched live as a permanent live, so older installations don't need new cables. A 2x Switched Live menu option lets separate inputs control heating demand and hot water demand. The PRT3 RF thermostat (216131) is not compatible.
A siphonic condensate trap lowers the risk of freezing. If the condensate pipe does freeze, the boiler gurgles and then shows "Ignition Lockout". You can thaw the pipe with warm water, but never boiling water. Frost protection works in every mode as long as the boiler has a permanent live supply. For extra protection against overheating, Ideal recommends the pump overrun kit (221792), which keeps water circulating for 4 minutes after shutdown.
An Ideal System Filter comes in the box, and it must be installed correctly or the warranty is affected. Recommended inhibitors include Fernox, Sentinel X100, Adey MC1, Scalemaster SM-1 PRO and Calmag CM100. Do not fill the system with artificially softened water. Before plastic pipework is connected, at least 1 metre of copper pipe must run from both the flow and return connections.
The boiler is fully serviceable from the front. It has a ceramic burner, a front panel held by clips, and a menu with fault help, fault history and sensor readings. A "Service Due" reminder appears once the boiler has been installed for a year. Accessories include a rear flue outlet kit (55/80), a stand-off kit, balcony and soffit kits, and telescopic flues. The boiler contains no asbestos, mercury or CFCs.
Frequently Asked Questions (FAQs)
Can't find the answer you need? Here are some frequently asked questions about the Ideal MAX Logic Heat H30 Boiler, and we answer them below.