Dometic 3314851 Air Conditioner Instruction Manual
Dometic 3314851 Air Conditioner
Dometic 3314851 Instructions
Here we offer the Dometic 3314851 Air Conditioner manual completely free and in English. We have cataloged this manual in the Air Conditioners section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Dometic 3314851 Air Conditioner, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.
Product Images
Dometic 3314851 Air Conditioner Specifications
| Feature | Specification |
|---|---|
| Air Distribution Box (ADB) Model | 3314851.000 |
| Control Type | Integral mechanical (rotary selector switch and thermostat knob) |
| Compatible Rooftop Units | 457915, B57915, 459516, B59516, 540315, 540316, 640312, 640315 (and their .70X, .71X, .80X, .83X, .84X, C35X, C85X versions) |
| Nominal Cooling Capacity (Compatible Units) | 11,000 BTU/h (640312), 13,500 BTU/h (457915, B57915, 540315, 640315), 15,000 BTU/h (459516, B59516, 540316) |
| Power Supply | 120 VAC, 60 Hz, single phase |
| Refrigerant | R-410A, 17.5 to 29.5 oz depending on model |
| Compressor Rated Load Amps | 10.5 to 13.3 A depending on model |
| Compressor Locked Rotor Amps | 53.0 to 70.0 A depending on model |
| Fan Motor Rated Load Amps | 2.0 to 3.5 A depending on model |
| Fan Motor Locked Rotor Amps | 5.6 to 10.0 A depending on model |
| Minimum Wire Size | No. 12 AWG copper, up to 7.3 m (24 ft) run |
| Circuit Protection | 20 A time-delay fuse or circuit breaker (supplied by the installer) |
| Minimum Generator Size | 3.5 kW (1 unit) / 5.0 kW (2 units) |
| Roof Opening | 36.1 cm x 36.1 cm (14-1/4 in x 14-1/4 in), ±3 mm |
| Roof Rafter Spacing | Minimum 40.6 cm (16 in) on center |
| Roof-to-Ceiling Thickness | 3.8 cm to 15.2 cm (1-1/2 in to 6 in) |
| Maximum Roof Slope | 15° (457915, B57915, 459516, B59516, 540315, 540316); 8° (640312, 640315) |
| Roof Load Requirement | 65 kg while the RV is moving (a 100 kg static load design normally meets this) |
| Selector Switch | 8 positions including OFF (High/Medium/Low Cool, High/Medium/Low Fan, Optional Heat) |
| Thermostat Range | Approx. 18.3°C to 32.2°C (65°F to 90°F), measured at the ADB inlet |
| Ceiling Template Bolt Torque | 4.5 to 5.5 N·m (approx. 40 to 50 in-lb), 4 bolts tightened evenly |
| ADB Mounting Hardware | 4 bolts, 2 sheet metal screws, 8 wood screws (supplied) |
| Unit Electrical Connection | 6-pin polarized plug to the electronic control box |
| Duct Divider Position | 14.2 cm (approx. 5-5/8 in) from the rear of the roof opening, aluminum side toward the rear |
| Optional Accessory | Electric heat strip |
| Air Filter Service Interval | At least every two weeks of operation |
| Applicable Codes | ANSI/NFPA 70 (NEC), ANSI/NFPA 1192 (USA); CSA C22.1 Parts I and II, CSA Z240 RV Series (Canada) |
| Manual Form Number | 3315941.000 (Portuguese, 08/16); English 3315079.016 |
Dometic 3314851 Air Conditioner Details
The Dometic 3314851 is a ceiling-mounted air distribution box (ADB) with an integral mechanical control. It pairs with a range of Dometic rooftop air conditioners built for recreational vehicles. The system can go in when the RV is built or be added later, and one person can do the installation with brief help from an assistant. The manual says a qualified service technician must install and service the product. It also forbids any modification and any accessory that Dometic has not authorized in writing.
The rooftop unit normally sits over an existing roof vent opening. If there is no vent, a single unit goes slightly forward of the center of the RV and centered side to side. With two units, place one a third of the way back from the front and the other two thirds of the way back. When sizing the cooling, consider the RV's size, window area, insulation, the climate where it will be used, and the comfort level you want. Before installing, check the ceiling for obstructions such as doors, partitions, curtains and light fixtures.
Before cutting into the roof, turn off the gas supply and disconnect both the 120 VAC power and the positive 12 VDC battery terminal. Frame any new opening between rafters with wood at least 1.9 cm (3/4 in) thick. This framing supports the ceiling and stops the unit from pulling air out of the roof cavity. Never create a low spot in the roof, because standing water will cause leaks. Leave at least 38.1 cm (15 in) of supply cable showing at the front of the opening so it is easy to connect to the junction box.
Lift the unit onto the opening, using the roof gasket as a guide. Do not slide it, because sliding can damage the gasket. Inside the RV, you trim the duct divider to match the ceiling thickness by removing between zero and nine rows, as shown in a reference table. Install the ceiling template with four bolts, using the pattern for your model: positions A, D, E and H, or B, C, F and G. Overtightening can crack the base pan, and undertightening can leave a poor seal that leaks.
For the wiring, connect white to white and black to black, and fasten the bare copper ground under the ground clip. Wrap the connectors in electrical tape so vibration does not loosen them. Once the ADB is lined up with the template, put in the screws before fitting the loose front and rear vent doors. The filter goes into the return air grille, which slides into a slot on the ADB and swings up to lock in place.
In cooling mode, High Cool gives the most cooling and dehumidification, and Low Cool is best for holding the temperature or running overnight. The fan keeps running while the compressor cycles off, so the temperature stays even. After switching the compressor off by hand, wait at least two minutes before restarting it to avoid short cycling and overload. The optional heat strip is meant for chilly mornings and does not replace a furnace. The thermostat does not cycle it. A sliding lever opens and closes the central air outlet.
For upkeep, wash the filter in warm soapy water and never run the unit without it. Clean the cabinet with a soft cloth and mild detergent, and do not use polish or abrasive powders. The fan motor is lubricated at the factory and needs no maintenance. If ice forms on the coil, clean the filter, set the thermostat warmer, or run the fan only. To cut heat gain, park in the shade, cover the windows, and start cooling early. The model and serial number labels are behind the return grille.
Frequently Asked Questions (FAQs)
Can't find the answer you need? Here are some frequently asked questions about the Dometic 3314851 Air Conditioner, and we answer them below.