Hunter SRC Plus Irrigation Controller Instruction Manual

Manual Hunter SRC Plus Irrigation Controller Instruction Manual

Hunter SRC Plus Irrigation Controller Instruction Manual

5/5 (1👤)
📕 Manual PDF 📄 32 Pages
★Rate It★

How many stars do you give this manual?

Hunter SRC Plus Irrigation Controller

Full Screen

Hunter SRC Plus Instructions

Here we offer the Hunter SRC Plus Irrigation Controller manual completely free and in English. We have cataloged this manual in the Irrigation Controllers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Hunter SRC Plus Irrigation Controller, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4

Hunter SRC Plus Irrigation Controller Specifications

Feature Specification
Manufacturer Hunter Industries Incorporated
Product Type Residential/Light Commercial Irrigation Controller
Models 600i, 601i (International), 900i, 901i (International)
Station Count 6 stations (600i/601i), 9 stations (900i/901i)
Installation Indoor only (not water or weather resistant)
Number of Programs 3 independent programs (A, B, C)
Station Run Time 0 to 99 minutes in 1-minute increments
Start Times 4 per day, per program, for up to 12 daily starts
Start Time Increments 15 minutes
Watering Schedule 7-day calendar or odd/even programming
Clock/Calendar 365-day clock/calendar; AM/PM or 24-hour format
Transformer Input 120 VAC, 60 Hz (230 VAC, 50/60 Hz International)
Transformer Output 26 VAC, 0.75 A
Transformer Included 120 VAC plug-in transformer included in 600i and 900i models
Station Output 24 VAC, 0.35 A per station
Maximum Output 24 VAC, 0.75 A (includes Master Valve circuit)
Pump Start Relay Current Draw Must not exceed 0.35 A
Minimum Distance to Pump/Pump Relay 15 ft (4.5 m)
Battery Backup 9-volt alkaline battery (not included)
Memory Non-volatile
Terminals AC, AC, R, RS, C, MV, station terminals
Master Valve / Pump Start Circuit Yes (MV terminal)
Weather Sensor Compatibility Hunter Mini-Clik, Rain-Clik, Freeze-Clik and other rain, wind or freeze sensors
Sensor Bypass Built-in, via RUN (BYPASS SENSOR) dial position
Remote Compatibility SRR or ICR remote via SmartPort (not included)
Central Control Compatibility Hunter IMMS (not included)
Protection Primary power surge protection, automatic short circuit protection
Diagnostics Hunter Quick Check circuit test
Recommended Field Wire 18 AWG multi-wire sprinkler cable
Mounting Screws 1" (25 mm), supplied
Overall Height 8¼" (22 cm)
Width 8½" (21 cm)
FCC Compliance Class B, Subpart J of Part 15

Hunter SRC Plus Details

The Hunter SRC Plus is Hunter's "Simple and Reliable Controller". You program it with a clearly labeled dial instead of a crowded keypad. The dial positions are RUN, RUN (BYPASS SENSOR), SET CURRENT DATE/TIME, SET PROGRAM START TIMES, SET STATION RUN TIMES, SET DAYS TO WATER, MANUAL – SINGLE STATION, MANUAL – ALL STATIONS and SYSTEM OFF. Four buttons raise or lower the flashing value, move to the next field and select program A, B or C. The basic rule is simple: the item that is flashing on the LCD is the item you are setting.

Mount the unit indoors, close to an outlet that is not controlled by a light switch and away from moisture and direct sunlight. Pull the bracket off the back of the housing and fix it slightly below eye level. Use anchors on drywall or masonry. Slide the controller down onto the bracket rails and add a screw through the lower central hole. Strip ¼ inch of insulation from each valve wire. Connect the white common wire to C and each station wire to its numbered terminal. Plug in the transformer only after all wiring is finished.

One start time is enough to run a whole program because stations water one at a time in numerical order. In the manual's example, a 6:00 AM start with stations set to 15, 15 and 20 minutes finishes at 6:50 AM. Stations with no run time are skipped. To remove a start time, scroll to 12:00 AM and press once more to reach OFF. If all four start times are off, that program stops watering but keeps its other settings. Hold a button for one second to scroll quickly.

Each program uses only one type of watering day: specific days of the week or odd/even dates. With odd-day watering, the 31st and February 29 are always off days. If you cancel odd or even watering, the weekdays you chose before become active again. Watering only happens when the dial is on RUN or RUN (BYPASS SENSOR). Turning the dial to SYSTEM OFF for two seconds shuts off any valve that is running. A reference label inside the door gives quick instructions and has space to record where each station is.

Manual single-station watering runs one station once and then returns to the normal schedule without changing it. Manual all-stations watering lets you adjust run times and start from any station. It then runs in order and never goes back to earlier stations. With One Touch Manual Start, you hold the advance button for two seconds to run stations without using the dial. It defaults to program A and starts after a two-second pause.

Hunter Quick Check finds field wiring shorts, such as a faulty solenoid or a bare common wire touching a station wire. Press the four designated buttons together and every LCD segment lights up. Then press the advance button to scan all station terminals for a high-current path. A shorted station shows its number followed by ERR. To reset the controller to factory defaults, hold the designated buttons, press and release RESET, then let go. The display then shows 12:00AM.

For a rain sensor, connect the sensor wires to RS and C, and move the valve common to RS. If you use a pump relay, connect its common to RS as well. For SRR or ICR remotes, install the SmartPort in a ½" female PVC tee about 12" below the controller. Connect red to the left AC terminal, white to the other AC terminal and blue to R. Lengthening the harness can cause ERR messages, so use shielded cable or the SRR-SCWH harness, which has 25 feet of shielded cable.

The non-volatile memory keeps programs indefinitely. Without a battery, the clock stops during a power outage and starts again when power returns. With a 9-volt battery installed, the clock keeps running for several days. If the display reads "No AC", check the power and the transformer. If the display freezes, unplug the unit, remove the battery, wait a few seconds, then restore power and reprogram.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Hunter SRC Plus Irrigation Controller, and we answer them below.


Can the Hunter SRC Plus be installed outdoors?
No. The SRC Plus is not water or weather resistant. It must be installed indoors or in a protected area away from moisture and direct sunlight.

How many programs and start times does the SRC Plus offer?
It has three independent programs (A, B and C). Each can have up to 4 start times per day, for a maximum of 12 daily starts.

Why does my controller water the same area several times?
Usually too many start times have been entered. One start time runs all stations in the program in order, so extra start times repeat the whole cycle.

Will the 9-volt battery run my sprinklers during a power outage?
No. The battery only keeps the clock running for several days. The program itself is kept in non-volatile memory. Valves will not operate until AC power returns.

How do I temporarily override my rain sensor?
Turn the dial to RUN (BYPASS SENSOR). The sensor is ignored and automatic watering continues. Return the dial to RUN to use the sensor again.

What does a station number followed by ERR mean?
There is a fault in the wire going to that valve. Check the wire for continuity, repair any shorted wire and make sure all connections are good and watertight.

What does the ERR message alone mean?
Electrical noise is getting in through the SmartPort wiring harness. This usually happens when the harness has been extended. Replace the extension with shielded cable.

Can I connect a pump directly to the controller?
No. You must use a pump start relay that draws no more than 0.35 A, mounted at least 15 ft (4.5 m) from the controller. Connecting a pump directly can damage the controller.

How do I turn off a single program without stopping the whole system?
Set all four start times of that program to OFF. The program stops watering but keeps its run times and watering days.

Why are some days skipped with odd-day watering?
With odd-day watering, the 31st of any month and February 29 are always off days.

How do I completely reset the controller to factory settings?
Hold down the designated buttons, press and release the RESET button in the wiring compartment, and then release the buttons. The display will show 12:00AM and all programs will be erased.

What should I do if the display freezes?
A power surge is the likely cause. Unplug the transformer, remove the battery, wait a few seconds, then restore power and reprogram the controller.