Here we offer the Vaillant EcoTEC Plus 620 Boiler manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Vaillant EcoTEC Plus 620 Boiler, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5

Vaillant EcoTEC Plus 620 Boiler Specifications

Feature Specification (Natural Gas - G20) Specification (Liquefied Petroleum Gas - G31)
General
Designated Country GB, IE GB, IE
Permitted Gas Boiler Category II2H3P II2H3P
CE / UKCA PIN 0063CU3910 0063CU3910
Gas Connection, Boiler Side 15 mm 15 mm
Flow/Return Heating Connections, Boiler Side G 3/4 ″ G 3/4 ″
Flow/Return Cylinder Connections, Boiler Side – –
Domestic Hot/Cold Water Connections, Boiler Side – –
Expansion Relief Valve Connection 15 mm 15 mm
Condensate Discharge Hose Connection 19 mm 19 mm
Air/Flue Pipe Connection 60/100 mm 60/100 mm
Capacity of Heating Expansion Vessel 10 l 10 l
Pre-charge Pressure of Heating Expansion Vessel 70 kPa (700 mbar) 70 kPa (700 mbar)
Min. Flue Gas Temperature 35 ℃ 35 ℃
Max. Flue Gas Temperature 85 ℃ 85 ℃
Approved Gas Boiler Types C13, C33, C43, C53 C13, C33, C43, C53
NOx Class 6 6
Weight with Packaging (incl. accessories) 37 kg 37 kg
Empty Weight of Product 32 kg 32 kg
Weight Ready for Operation (filled) 37 kg 37 kg
Output/Heat Input (Heating Mode)
Gas Connection Pressure 2.0 kPa (20.0 mbar) 3.7 kPa (37.0 mbar)
NOx Emission, Weighted (EN 15502-2-1) 33.20 mg/kWh 38.75 mg/kWh
30% Efficiency 108.8 % N/A
Max. Gas Volume Flow (DHW generation potential) 2.59 m³/h 1.9 kg/h
Nominal Heat Output Range at 40/30 °C 2.9 to 21.7 kW 5.5 to 21.2 kW
Nominal Heat Output Range at 50/30 °C 2.8 to 21.2 kW 5.4 to 20.6 kW
Nominal Heat Output Range at 60/40 °C 2.6 to 20.3 kW 5.1 to 20.0 kW
Nominal Heat Output Range at 80/60 °C 2.5 to 19.8 kW 5.0 to 19.8 kW
Nominal Heat Input Range for Heating (Hi) 2.7 to 20.4 kW 5.2 to 20.4 kW
Nominal Heat Input Range for Heating (Hs) 3.0 to 22.6 kW 5.7 to 22.2 kW
Min. Flue Gas Mass Flow Rate 1.23 g/s (4.43 kg/h) 2.53 g/s (9.11 kg/h)
Max. Flue Gas Mass Flow Rate 12.34 g/s (44.42 kg/h) 11.95 g/s (43.02 kg/h)
Max. Heat Output for Domestic Hot Water (potential) 27.2 kW 26.7 kW
Nominal Heat Input for Domestic Hot Water (Hi) (potential) 24.5 kW 24.5 kW
Nominal Heat Input for Domestic Hot Water (Hs) (potential) 27.2 kW 26.7 kW
Heating Adjustment Range 2.7 to 20.4 kW 5.2 to 20.4 kW
Heating Circuit
Max. Flow Temperature 85 ℃ 85 ℃
Flow Temperature Adjustment Range (factory setting: 75 °C) 30 to 80 ℃ 30 to 80 ℃
Permissible Operating Pressure, Heating 0.25 MPa (2.50 bar) 0.25 MPa (2.50 bar)
Nominal Circulation Water Volume (ΔT = 20 K, 80/60 °C) 878 l/h 878 l/h
Approx. Condensate Rate (pH 3.5-4.0, 50/30 °C) 2.0 l/h 2.0 l/h
Remaining Pump Head at Nominal Circulation Water Volume 0.025 MPa (0.250 bar) 0.025 MPa (0.250 bar)
Electrics
Rated Voltage 230 V~ 230 V~
Mains Frequency 50 Hz 50 Hz
Permissible Connected Voltage 190 to 253 V~ 190 to 253 V~
Built-in Fuse (slow-blow) 4 A 4 A
Max. Power Consumption in Heating Mode 81.7 W 81.7 W
Max. Power Consumption in Domestic Hot Water Mode 102 W 102 W
Electrical Standby Energy Consumption < 2 W < 2 W
IP Rating IPX5D IPX5D

Vaillant EcoTEC Plus 620 Boiler Details

The Vaillant EcoTEC Plus 620 Boiler boasts an intuitive and user-friendly interface, designed for effortless operation. Its clear display works in conjunction with soft-touch control elements, allowing users to easily navigate menus, adjust desired flow temperatures for heating, and manage domestic hot water settings when connected to a cylinder. Essential symbols on the display provide immediate feedback on boiler status, including burner modulation, system pressure, and active modes. The interface also supports language selection and a convenient button lock feature to prevent accidental changes, ensuring peace of mind for homeowners.

Beyond basic controls, the EcoTEC Plus 620 is engineered for seamless integration with a range of advanced systems, significantly enhancing its functionality and energy efficiency. It is compatible with Vaillant's sensoROOM pure (VRT 50/2) room temperature control, enabling sophisticated time-dependent heating schedules and weekly planners. Furthermore, its eBUS compatibility extends to smart home solutions, weather-compensated controls, and the myVAILLANT Connect (VR 940f) communication unit. This connectivity allows for remote control via the Vaillant app, offering users unparalleled convenience and optimization capabilities.

At the heart of the EcoTEC Plus 620 is Vaillant’s cutting-edge Sitherm Pro™ technology, which provides intelligent combustion regulation. This adaptive Siemens optimization automatically manages the gas-air ratio, eliminating the need for manual adjustments within the same gas family. This not only simplifies installation but also ensures the boiler consistently operates at peak efficiency, minimizing emissions and energy waste. The system can even display approximate energy consumption data, offering valuable insights into heating and hot water usage patterns for better management.

Safety and reliability are paramount for the EcoTEC Plus 620. The boiler incorporates multiple built-in protective measures to ensure secure operation. These include sophisticated overheating safety protocols that prevent critical temperature excursions and a robust frost protection system that activates the pump and burner at specific low temperatures (e.g., pump at 12°C, burner at 5°C) to prevent freezing damage. Additionally, it features intelligent detection for condensate drain blockages, which automatically shuts down the boiler to prevent complications, thus safeguarding the appliance and property.

To ensure a long and efficient service life, the Vaillant EcoTEC Plus 620 requires annual inspection by a qualified competent person. The boiler proactively signals maintenance needs through specific messages (I.XXX codes) on its display, alerting users to scheduled servicing or low system pressure. Vaillant supports this with a two-year guarantee, subject to an annual service. The product is also part of the esteemed Benchmark Scheme, which upholds high standards for installation, commissioning, and regular servicing, promoting optimal safety and performance.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Vaillant EcoTEC Plus 620 Boiler, and we answer them below.


What is the primary function of the Vaillant EcoTEC Plus 620 Boiler?
The Vaillant EcoTEC Plus 620 is primarily intended as a heat generator for sealed heating installations and for domestic hot water generation when connected to an external domestic hot water cylinder.

How do I know if my boiler requires maintenance?
If the symbol (spanner icon) is shown in the display, the product requires maintenance work. You should consult a competent person. Maintenance is recommended annually.

What should I do if I smell gas near the boiler?
If you smell gas, immediately avoid the room, open windows, do not use naked flames or electrical switches, close the emergency control valve, warn others, evacuate the building, and then alert emergency services and the gas supply company from outside.

How can I temporarily switch off the boiler, especially during periods of frost?
To temporarily decommission the product while maintaining frost protection, briefly press the standby button. The display will go out, but frost protection for the heating installation remains active. If there's no risk of frost, you can switch it off at the fused spur box.

How do I check and maintain the pressure of my heating system?
You can check the filling pressure on the basic display as a value or a five-level symbol. The recommended filling pressure is at least 1 bar (0.1 MPa). If it falls below 0.8 bar (0.08 MPa), you should top up the heating water as instructed by a competent person.

Does the Vaillant EcoTEC Plus 620 automatically adjust the gas-air ratio?
Yes, the boiler features Sitherm Pro™ technology for intelligent combustion regulation. This adaptive optimization automatically manages the gas-air ratio, meaning it does not require manual adjustment within the same gas family.

What is the importance of water quality for the heating system?
Unsuitable heating water (e.g., extremely calciferous, corrosive, or chemically contaminated) can damage seals, diaphragms, and internal components, leading to material damage and operational noise. It's crucial to use suitable heating water and check its quality and pH value regularly.

What frost protection features are built into the boiler?
The appliance has a built-in frost protection device. If the boiler water temperature falls below 12 °C, the pump will operate. If the temperature doesn't reach 15 °C after 30 minutes, or drops to 5 °C at any time, the burner will activate until the temperature reaches 35 °C.

What does fault code F.022 typically indicate?
Fault code F.022 indicates no or insufficient water in the product, or that the water pressure is too low. Measures include checking the filling pressure, topping up the heating water, and checking for system leakages.

How can I set the heating flow temperature on the boiler?
From the basic display, press the heating mode button. The current flow temperature will be shown, allowing you to set your desired flow temperature. If a sensoROOM pure (VRT 50/2) or other system control is connected, this setting should be managed via the control unit.

Can I lock the boiler's control panel to prevent unauthorized changes?
Yes, the Vaillant EcoTEC Plus 620 features a button lock. You can activate it through MENU → SETTINGS → Button lock to protect the control panel from unauthorized manipulation. To deactivate, press and hold for four seconds.

What is the purpose of the Benchmark Scheme mentioned in the manual?
The Benchmark Scheme, which Vaillant is a licensed member of, aims to improve installation, commissioning, and servicing standards for domestic heating and hot water systems in the UK. It ensures that the boiler is installed correctly and serviced regularly for optimal safety and performance, and is key for warranty validation.

How frequently should the EcoTEC Plus 620 boiler be serviced?
An annual inspection of the product by a competent person is a prerequisite for ensuring permanent operational readiness, safety, reliability, and a long working life. The service interval must not be greater than 1 year.

Related product manuals

Go up