Here we offer the Vaillant Ecofit Pure 435 Boiler manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Vaillant Ecofit Pure 435 Boiler, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4

Vaillant Ecofit Pure 435 Boiler Specifications

Category Specification Value (Vaillant Ecofit Pure 435)
Heating Data Max. Flow Temperature Adjustment Range 10 – 80 ℃ (Default: 75 ℃)
Maximum Permissible Pressure 0.3 MPa (3.0 bar)
Nominal Water Flow (ΔT = 20 K) 1,535 l/h
Nominal Water Flow (ΔT = 30 K) 1,023 l/h
Approx. Condensate Volume (50/30 °C) 3.65 l/h (pH 3.5-4.0)
Performance (G20 Natural Gas) Maximum Heat Output 35 kW
Effective Output Range (40/30 °C) 7.6 – 37.8 kW
Effective Output Range (50/30 °C) 7.0 – 35.8 kW
Effective Output Range (80/60 °C) 7.2 – 34.8 kW
Domestic Hot Water Heat Output (P) 7.1 – 35.0 kW
Maximum Heat Input – Heating (Q max.) 35.7 kW
Minimum Heat Input – Heating (Q min.) 7.2 kW
Maximum Heat Input – Hot Water (Q max.) 35.7 kW
Minimum Heat Input – Hot Water (Q min.) 7.2 kW
General Data Gas Category I2H
Gas Pipe Diameter 1/2 inch
Heating Connections Diameter 3/4 inch
Condensate Drain Pipework (min.) 21.5 mm
G20 Gas Supply Pressure 2.0 kPa (20.0 mbar)
NOx Class 6
Product Dimensions (Width x Depth x Height) 375 mm x 295 mm x 602 mm
Net Weight 23 kg
Weight when filled with water 28 kg
Nominal Efficiency (80/60 °C) 97.5 %
Nominal Efficiency (50/30 °C) 100.2 %
Nominal Efficiency (40/30 °C) 106.0 %
Electrical Data Electric Connection 230 V / 50 Hz
Built-in Fuse (slow-blow) T2/2A, 250V
Max. Electrical Power Consumption 50 W
Standby Electrical Power Consumption 2 W

Vaillant Ecofit Pure 435 Boiler Details

The Vaillant Ecofit Pure 435 boiler is distinguished by its high efficiency and intelligent design. As a licensed member of the Benchmark Scheme, it guarantees adherence to rigorous industry standards for installation, commissioning, and servicing, ensuring optimal performance and compliance with Building Regulations. Its advanced engineering results in very low heat loss from the appliance casing during operation, a key factor in its overall energy efficiency.

This low heat loss means that compartment ventilation is not required, simplifying installation and offering greater flexibility in placement. Safety is a core consideration, with the manual providing comprehensive action-related warnings covering handling, gas and flue gas leaks, and electrical hazards. It also alerts installers and users to risks from explosive materials, corrosion from unsuitable air, and frost damage, ensuring a secure operational environment.

For qualified installers, the Ecofit Pure 435 offers an accessible installer level. This advanced interface provides deep insights into the boiler's operation, allowing for monitoring of live status codes and execution of various check programmes. These include purging the heating and hot water circuits, operating at maximum or minimum load, and engaging a filling mode. These tools facilitate precise system tuning and efficient commissioning.

Long-term reliability is supported by detailed inspection and maintenance guidelines. The manual emphasizes using original seals for component replacement. Key maintenance tasks include checking and adjusting CO₂ content, thoroughly cleaning the heat exchanger, inspecting the burner and ignition electrode, and cleaning the condensate trap. Adhering to these minimum intervals, which can be as frequent as annually or at least every five years, is crucial for sustained performance.

The boiler intelligently adapts to heating demands with features like adjustable burner anti-cycling time. This mechanism minimizes frequent burner on-off cycles, reducing energy losses and enhancing system longevity. Troubleshooting is streamlined via a fault memory that stores the last 10 fault messages (F.xx codes), aiding quick diagnosis. Installers can also easily reset parameters to factory settings when necessary.

The efficient operation of the Ecofit Pure 435 produces condensate, and its management is well-documented. The instructions specify suitable materials for drain pipework, emphasizing a continuous fall and frost protection measures. Furthermore, Vaillant encourages responsible practices, providing guidance on the correct recycling and disposal of the product and its packaging at the end of its lifecycle, aligning with environmental standards.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Vaillant Ecofit Pure 435 Boiler, and we answer them below.


What is the Benchmark Scheme and why is it important for the Vaillant Ecofit Pure 435?
The Benchmark Scheme ensures that the boiler is installed, commissioned, and serviced by a competent person according to manufacturer's instructions and Building Regulations, guaranteeing optimal performance and safety.

Does the Ecofit Pure 435 require compartment ventilation?
No, the Vaillant Ecofit Pure 435 is a very high-efficiency appliance with low casing heat loss, so compartment ventilation is not required.

What should I do if I smell gas in my building?
Immediately avoid rooms with the smell, open windows for ventilation, do not use naked flames or electrical switches, close the emergency control valve or main isolator if safe, warn others, evacuate the building, and then notify the gas supply company.

How often should the Vaillant Ecofit Pure 435 boiler be inspected and maintained?
It is recommended that the boiler undergoes annual inspection and maintenance. For products not on an annual service agreement, maintenance must be carried out at least once every five years.

What is the purpose of the burner anti-cycling time?
The burner anti-cycling time prevents frequent switching on and off of the burner, which reduces energy losses and enhances the boiler's overall energy efficiency and lifespan.

Can I use any additives in the heating water for the Ecofit Pure 435?
No, only specific additives (e.g., Fernox F1, Sentinel X 100) are recommended as compatible with Vaillant products. Always follow the additive manufacturer's instructions and consult the boiler manual for approved types.

How can I check the operating status of my boiler?
You can access the 'Live Monitor' via the installer level to view status codes (S.xx) that provide information on the product's current operating status.

What does fault code F.22 indicate?
Fault code F.22 signifies a safety switch-off due to low water pressure, potentially caused by insufficient water in the product, a defective water pressure sensor, or loose/defective cabling to the pump or sensor.

What are the dimensions of the Vaillant Ecofit Pure 435 boiler?
The product dimensions are 375 mm (width) x 295 mm (depth) x 602 mm (height).

How do I reset the boiler to factory settings?
To reset to factory settings, navigate to diagnostics code D.096 in the installer level, set the code to '1', and confirm.