Here we offer the Triangle Tube Prestige Solo 175 manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Triangle Tube Prestige Solo 175, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4

Triangle Tube Prestige Solo 175 Boiler Specifications

Specification Value
Fuel Type Natural Gas or Propane
Input (BTU/hr) 30,900 - 170,000
DOE Heating Capacity (BTU/hr) 157,000
Net AHRI Rating (BTU/hr) 137,000
AFUE 95%
Shipping Weight 128 lbs (58 kg)
Boiler Water Volume 5 Gallons (19 L)
Minimum Flow Rate at Full Input 8 GPM
Boiler Width 19-3/4 inches (502 mm)
Boiler Height 36-9/16 inches (928 mm)
Boiler Depth 17-5/16 inches (440 mm)
Boiler Supply Connection 1-1/4 inch NPT
Boiler Return Connection 1-1/4 inch NPT
Gas Connection 3/4 inch NPT
Vent Outlet / Combustion Air Inlet 3 inches
Pressure Relief Valve Connection 3/4 inch NPSC

Triangle Tube Prestige Solo 175 Details

The Triangle Tube Prestige Solo 175 boiler is managed by the advanced CTRLMax/ACVMax Boiler Management System, designed for flexible and efficient heating. Its graphical display simplifies navigation with intuitive icons and plain English descriptions, eliminating the need for complex code charts. Users can easily access the Home Screen for real-time operating status, including supply and return temperatures, burner activity, and active heating or domestic hot water calls. Status line messages provide clear updates on the boiler's current state.

Customizing the boiler's operation is straightforward with the EZ Setup menus, allowing quick adjustments for heating, domestic hot water (DHW), language, and temperature units. The CH/DHW Operation menu provides simple toggles to enable or disable central heating or DHW functions as needed. For detailed monitoring, the "Boiler Information" section offers real-time data on parameters like firing rate, flue temperature, and system pressure, with a logging function for historical trends over 24 hours.

Safety is paramount, and the Prestige Solo 175 incorporates several critical features. It includes a factory-installed Low Water Cut Off (LWCO) device that monitors system pressure, shutting down the unit if pressure falls below 7.2 psig. A built-in freeze protection feature activates circulators at 46°F (8°C) and fires the burner at 42°F (6°C) to prevent damage to the boiler itself. The manual emphasizes the installation of a minimum of two hard-wired carbon monoxide detectors with alarms for occupant safety.

The boiler's unique heat exchanger design facilitates operation in a highly efficient condensing mode, eliminating the need for complex return water temperature regulation in radiant heating applications. This design is even compatible with non-oxygen barrier tubing, although it's crucial not to combine it with SMART indirect water heaters in such systems. Proper boiler system fluid maintenance, including pH levels and hardness, is critical for longevity, with strict warnings against petroleum-based cleaning compounds.

Installation and maintenance are streamlined, with the Prestige Solo 175 designed for wall mounting using the provided bracket and approved for zero clearance to combustibles (excluding vent and boiler piping). It operates as a Category IV or Direct Vent appliance, requiring a dedicated, gas-tight polypropylene venting system and never sharing a common vent with other appliances. The ACVMax control also supports advanced configurations, including a cascade function for operating up to six boilers together and a Modbus interface for integration with building management systems (BMS).

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Triangle Tube Prestige Solo 175, and we answer them below.


What is the function of the CTRLMax (ACVMax) Boiler Management System?
It's a flexible, easy-to-use graphical interface that monitors and controls the Prestige Solo 175 to provide heat efficiently, offering real-time status, diagnostics, and various settings adjustments.

Does the Prestige Solo 175 have freeze protection?
Yes, it has a built-in freeze protection feature that activates circulators at 46°F (8°C) and fires the burner at 42°F (6°C) to protect the boiler itself, ending at 60°F (15°C).

What are the requirements for Carbon Monoxide (CO) detectors with this boiler?
A minimum of two hard-wired CO detectors with alarms and battery back-up are required: one in the mechanical room with the boiler and another in the living area outside sleeping areas.

Can the Prestige Solo 175 be installed with shared venting?
No, the Prestige Solo 175 is a Category IV appliance and *must not* be installed into a common vent with any other gas or oil appliances to prevent flue gas spillage and malfunction.

What type of water is recommended for the boiler system?
The boiler fluid pH level should be between 6.0 and 8.0, and water hardness less than 7 grains. Petroleum-based cleaners or sealing compounds are prohibited. The system should be flushed and treated with an approved inhibitor.

Is the Prestige Solo 175 suitable for radiant heating systems with non-oxygen barrier tubing?
Yes, its heat exchanger design allows operation with non-oxygen barrier tubing, eliminating the need for return water temperature regulation in such applications. However, it should not be used with SMART indirect water heaters in these systems.

How is boiler status and diagnostic information accessed?
The CTRLMax/ACVMax Home Screen displays basic operating info. More detailed real-time data, including Boiler Firing Rate, temperatures, pressure, and lockout history, can be accessed through the "Boiler Information" and "Lockout History" menus.

What are the clearance requirements for installation?
The Prestige Solo 175 is approved for zero clearance to combustibles, except for vent and boiler piping. Recommended clearances for serviceability are 24 inches top/front/bottom and 6 inches sides.

Can the boiler be controlled by an external modulating system?
Yes, the Prestige Solo 175 can accept an analog 0-10 VDC signal from an external modulating boiler controller to manage its firing rate, requiring specific wiring and programming.

What should I do if I smell gas?
Do not attempt to light any appliance, touch electrical switches, or use phones in the building. Immediately call your gas supplier from a neighbor's phone. If unavailable, call the fire department.

How often should the Prestige Solo 175 be serviced?
It requires annual inspection and service by a qualified technician, preferably at the start of the heating season, in addition to periodic owner maintenance.

Can multiple Prestige Solo boilers be used together?
Yes, the ACVMax control includes a cascade function that allows up to six Prestige Solo boilers to operate together as one system without external controllers.

Is fuel conversion from natural gas to propane possible?
Yes, the unit is shipped with a propane conversion kit for changing from natural gas. It's crucial to ensure proper burner setup for the correct fuel type before operation.

What does 'Low Water Pressure' status mean on the display?
It indicates the system pressure has dropped to 10.1 psi. The boiler will still operate until pressure falls below 7.2 psi, at which point it enters a lockout. Increase system pressure to 14.5 psi to clear the warning.

What is the purpose of the condensate drain assembly and how is it maintained?
The condensate drain assembly prevents flue gases from entering the drain line and must always be filled with water. Owners should check it monthly for blockages and ensure it's filled, pouring water through the fill plug if necessary.