Here we offer the Triangle Tube Prestige Solo 110 manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Triangle Tube Prestige Solo 110, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Imagen 6
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5
Miniatura 6

Triangle Tube Prestige Solo 110 Boiler Specifications

Feature Specification
Fuel Type Natural Gas / Propane
Input Range 20,000 - 110,000 BTU/hr
DOE Heating Capacity 102,000 BTU/hr
Net AHRI Rating 89,000 BTU/hr
Annual Fuel Utilization Efficiency (AFUE) 95%
Shipping Weight 103 lbs (47 kg)
Height 36-9/16" (928 mm)
Width 19-3/4" (502 mm)
Depth 17-5/16" (440 mm)
Boiler Supply Connection 1" NPT
Boiler Return Connection 1" NPT
Gas Connection 1/2" NPT
Pressure Relief Valve Connection 3/4" NPSC
Combustion Air Inlet Diameter 3"
Vent Outlet Diameter 3"
Minimum Flow Rate (at full input) 5 GPM
Natural Gas Orifice Size 0.242" (6.15 mm)
Propane Orifice Size 0.175" (4.45 mm)
Minimum Operating System Pressure 10 psig
Low Water Cut Off (Lockout) Below 7.2 psig
Maximum System Pressure 25 psig
Maximum Boiler Temperature (High Limit) 210°F (99°C)

Triangle Tube Prestige Solo 110 Details

The Triangle Tube Prestige Solo 110 is managed by the advanced CTRLMax/ACVMax Boiler Management System. This intuitive interface ensures efficient heating by monitoring and controlling the boiler's operations. Its graphical display presents information in plain English, eliminating the need for complex code charts and simplifying user interaction.

Navigation is straightforward, utilizing four arrow buttons (UP, DOWN, LEFT, RIGHT) and a central OK button for selections. An "INSTALLER" button provides technicians with advanced access, password-protected. The system offers an "EZ Setup" feature, enabling quick customization of common settings, making installation and initial configuration remarkably simple.

The Home Screen provides a comprehensive overview of the boiler's status, including current supply and return temperatures, burner activity, and active central heating (CH) or domestic hot water (DHW) calls. The "Boiler Information" menu offers detailed real-time operational data, from firing rates and ionization current to flue and outdoor temperatures.

A robust "Lockout History" feature records the last eight operational lockouts, detailing when they occurred and providing a snapshot of boiler conditions at that specific moment. This diagnostic tool is invaluable for troubleshooting, clearly displaying lockout messages, potential cures, and corresponding reference codes for rapid issue resolution.

The Prestige Solo 110 incorporates several crucial safety features. A factory-installed pressure sensor acts as a Low Water Cutoff (LWCO), ensuring the boiler shuts down if water pressure drops below 7.2 psig to prevent damage. An integrated freeze protection feature activates pumps at 46°F and the burner at 42°F to safeguard the boiler, though external system protection is also recommended in unheated spaces.

Beyond basic operation, the unit supports sophisticated system configurations. It includes capabilities for outdoor reset control, which optimizes boiler water temperature based on external conditions for enhanced efficiency. It also features mixing valve control for dual-temperature heating systems and a cascade function allowing up to six boilers to operate seamlessly as one integrated system.

For advanced building management, the Prestige Solo 110 offers a Modbus interface, facilitating communication with external Building Management Systems (BMS). Its design also considers various piping arrangements, recommending primary/secondary piping for optimal performance and offering flexible options for zoning with either circulators or zone valves.

Designed for longevity, the unit requires annual inspection and service by a qualified technician, alongside owner-level maintenance tasks. Its condensing design allows for high efficiency and flexibility in radiant heating applications, even accommodating non-oxygen barrier tubing in heating systems (though not recommended with SMART indirect water heaters).

The Prestige Solo 110 is engineered for versatility, capable of operating on both natural gas and propane. It comes factory-equipped for natural gas, with a dedicated conversion kit supplied for propane applications, ensuring adaptability to different fuel sources.

This wall-mounted unit is certified for indoor, conditioned space installations only. It features zero clearance to combustibles (excluding vent and boiler piping) and requires a minimum wall support capacity of 130 lbs. Its compact design and wall-mounting bracket simplify installation, provided proper clearances for serviceability are maintained.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Triangle Tube Prestige Solo 110, and we answer them below.


What should I do if I smell gas near the Prestige Solo 110?
Do not attempt to light any appliance, touch electrical switches, or use a phone in your building. Immediately call your gas supplier from a neighbor's phone and follow their instructions. If you cannot reach them, call the fire department.

What maintenance is required for the Triangle Tube Prestige Solo 110, and how often?
Annual service by a qualified technician is required, including checking for leaks, cleaning the condensate drain, inspecting the heat exchanger, and verifying combustion levels. Owners should perform periodic checks (daily, monthly, every 6 months) for obstructions, leaks, and proper operation of safety components like the pressure relief valve and carbon monoxide detectors.

What does the 'E37 Low Water' lockout message mean on my Prestige Solo 110?
The 'E37 Low Water' message indicates that the system water pressure has fallen below 7.2 psi, causing the boiler to shut down. You need to increase the system pressure to 14.5 psi to clear this warning and allow the boiler to automatically reset. If the problem persists, contact a qualified service technician.

Can the Prestige Solo 110 be installed in a garage?
Yes, it can be installed in a residential garage. However, it must be mounted a minimum of 18 inches (458 mm) above the floor level, and located or protected in a way that prevents damage from moving vehicles, according to NFPA 54/ANSI Z223.1.

Is the Prestige Solo 110 compatible with all types of heating system water?
The boiler fluid pH level must be maintained between 6.0 and 8.0, and water hardness should be less than 7 grains. Petroleum-based or non-boiler specific cleaning/sealing compounds must never be used. Avoid continual fresh makeup water and cold makeup water when the appliance is hot, as these can reduce heat exchanger life.

How does the freeze protection feature work on the Prestige Solo 110?
The ACVMax control system includes a freeze protection feature that monitors boiler water temperature. If the temperature drops to 46°F, system pumps are enabled. If it drops further to 42°F, the burner will operate at low fire. Freeze protection ends once the supply/system water temperature reaches 60°F. Note that this feature protects the boiler, not the entire heating system, and is disabled during a hard lockout.

What are the requirements for carbon monoxide detectors with the Prestige Solo 110?
Triangle Tube requires the installation of a minimum of two hard-wired carbon monoxide detectors with alarms and battery backup. One should be in the mechanical room where the boiler is located, and another in the living area outside sleeping areas. Always consult local authorities for additional requirements.

Can I adjust the gas valve outlet pressure on the Prestige Solo 110?
No, you should NOT adjust or attempt to measure the gas valve outlet pressure. The gas valve is factory-set for the correct outlet pressure for both natural gas and propane, and it requires no field adjustment. Tampering with this setting can result in damage or unsafe operation.

What should I do if the vent or combustion air piping becomes blocked?
Regularly check and remove any debris or obstructions from the vent termination and combustion air intake. If removing the blockage does not resolve the issue or if the blockage is not obvious, contact a qualified service technician to inspect the unit and the entire vent/combustion air system immediately.

Can I use my Prestige Solo 110 with a SMART indirect water heater and non-oxygen barrier tubing?
The Prestige Solo 110's heat exchanger design allows operation with non-oxygen barrier tubing in heating systems. However, it is explicitly stated that you should NOT install a SMART indirect water heater along with the Prestige Solo in systems with non-oxygen barrier tubing, as this can lead to premature failure of the SMART indirect water heater.

How is the Prestige Solo 110 controlled by an external system?
The boiler can directly accept an analog 0-10 VDC signal from an external modulating boiler controller to control its firing rate. Wiring involves connecting the external controller's output to specific low voltage terminals on the ACVMax control module, and the ACVMax control must be programmed to accept this modulation signal.

What is the typical operating pressure for the boiler system?
A typical residential system fill pressure is 12 psig. The system pressure will increase as the system temperature increases, but the operating pressure should never exceed 25 psig.