Vaillant Ecofit Pure 835 Boiler Instruction Manual

Manual Vaillant Ecofit Pure 835 Boiler Instruction Manual

Vaillant Ecofit Pure 835 Boiler Instruction Manual

5/5 (1👤)
📕 Manual PDF 📄 56 Pages
★Rate It★

How many stars do you give this manual?

Vaillant Ecofit Pure 835 Boiler

Full Screen

Vaillant Ecofit Pure 835 Boiler Instructions

Here we offer the Vaillant Ecofit Pure 835 Boiler manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Vaillant Ecofit Pure 835 Boiler, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4

Vaillant Ecofit Pure 835 Boiler Specifications

Feature Category Specification Value (VUW 356/6-3 (H-GB))
General Data Gas Category I2H
Diameter of Gas Pipe 1/2 inch
Diameter of Heating Connections 3/4 inch
Expansion Relief Valve Connection Pipe (min.) 15 mm
Condensate Discharge Pipe (min.) 21.5 mm
G20 Gas Supply Pressure 2.0 kPa (20.0 mbar)
Gas Flow at P max. – hot water (G20) 3.8 m³/h
Gas Flow at P max. – heating mode (G20) 2.7 m³/h
Gas Flow at P min. (G20) 0.762 m³/h
CE Number (PIN) CE-0063CP3646
SAP 2009/2012 Annual Efficiency 89.7%
Flue Gas Mass Rate (heating mode at P min.) 3.30 g/s
Flue Gas Mass Rate (heating mode at P max.) 11.6 g/s
Flue Gas Mass Rate (hot water handling mode at P max.) 16.1 g/s
Flue Gas Temperature (80 °C/60 °C at P max.) 82 °C
Flue Gas Temperature (50 °C/30 °C at P min.) 37 °C
NOx Class 6
Product Dimensions (Width) 390 mm
Product Dimensions (Depth) 295 mm
Product Dimensions (Height) 702 mm
Net Weight 33 kg
Weight when filled with water 38 kg
Power/Loading G20 Maximum Heat Output (Heating) 25 kW
Effective Output Range (P) at 40/30 °C 7.6 to 27.2 kW
Effective Output Range (P) at 50/30 °C 7.5 to 26.7 kW
Effective Output Range (P) at 80/60 °C 7.2 to 25.5 kW
Domestic Hot Water Heat Output (P) 7.1 to 35.0 kW
Maximum Heat Input – heating (Q max.) 25.7 kW
Minimum Heat Input – heating (Q min.) 7.2 kW
Maximum Heat Input – hot water (Q max.) 35.7 kW
Minimum Heat Input – hot water (Q min.) 7.2 kW
Heating Specific Max. Flow Temperature Adjustment Range 10 to 80 °C (default: 75 °C)
Maximum Permissible Pressure 0.25 MPa (2.50 bar)
Nominal Water Flow (ΔT = 20 K) 1,102 l/h
Nominal Water Flow (ΔT = 30 K) 876 l/h
Approximate Condensate Volume (50/30 °C) 2.57 l/h
Domestic Hot Water Specific Specific Flow Rate (D) (ΔT = 30 K) 16.5 l/min
Specific Flow Rate (ΔT = 35 K) 14.1 l/min
Minimum Permissible Pressure 0.03 MPa (0.30 bar)
Maximum Permissible Pressure 1 MPa (10 bar)
Recommended Pressure 0.2 MPa (2.0 bar)
Temperature Range 35 to 60 °C
Maximum Water Flow Rate 12.0 l/min
Electrics Electrical Connection 230 V / 50 Hz
Built-in Fuse (slow-blow) T2/2A, 250V
Max. Electrical Power Consumption 98 W
Standby Electrical Power Consumption 3 W
IP Rating IPX4D

Vaillant Ecofit Pure 835 Boiler Details

The Vaillant Ecofit Pure 835 combi boiler is designed as an efficient heat generator for closed heating systems and domestic hot water production. Its compact design allows for versatile installation, including within zones 2 or 3 of rooms containing a bath or shower, adhering to relevant wiring and building regulations in Great Britain and Ireland.

This product prioritizes safety with multiple integrated features. It includes an overheating safety mechanism that preemptively shuts down the boiler to prevent damage, requiring a simple reset. Furthermore, it boasts an internal frost protection device that activates the pump and, if necessary, the burner, to safeguard the boiler from freezing when temperatures drop.

A critical safety aspect involves its condensate management. The boiler will cease operation if the condensate drain becomes blocked, which can happen during freezing conditions. Users are advised to unblock external pipes using warm cloths. For installation, careful routing of the condensate discharge pipe with a continuous fall is essential to prevent blockages and ensure proper function.

The Ecofit Pure 835 comes equipped with a speed-regulated high-efficiency pump. This intelligent pump automatically adjusts its output to the hydraulic conditions of the heating installation, optimizing energy consumption. Should a low loss header be installed, the pump's speed regulation can be fixed to a specific value for consistent performance.

Maintaining proper heating water quality is crucial for the boiler's longevity and efficiency. The manual stresses the importance of checking the pH value (ideally between 6.5 and 8.5) and the presence of sedimentary materials or magnetite. It also advises against unsuitable additives and recommends specific, approved cleaning agents and inhibitors to prevent corrosion, especially given aluminium components.

For installations, the boiler is suitable for timber frame buildings when installed according to IGE/UP/7. Its high-efficiency design means that compartment ventilation is generally not required, as heat loss from the casing is minimal. Various flue outlet configurations are possible, including horizontal and vertical concentric types (C13, C33, C43, C53), requiring specific clearances and, in some cases, a terminal protection kit.

The boiler’s operating concept includes an ‘installer level’ accessible to competent persons, offering detailed diagnostics and check programmes. These programmes facilitate tasks like purging the heating circuit, testing maximum and minimum load operations, and preparing the system for filling or draining, streamlining the commissioning and maintenance processes.

Setting the domestic hot water temperature is also managed through the interface, with a significant emphasis on Legionella prevention. The manual advises ensuring end-users are aware of anti-Legionella measures, noting that Legionella can multiply at temperatures below 60 °C. Additionally, if water hardness exceeds 3.57 mol/m³, the hot water temperature should not exceed 50 °C.

Regular inspection and maintenance are paramount for validating the warranty and ensuring safe, efficient operation. The manual provides a comprehensive list of annual checks, including verifying flue integrity, gas flow rates, CO² content, and the condition of various components. After servicing, the Benchmark Service Interval Record section must be completed by a competent person.

For convenience and ease of use, the unit features a Live Monitor that displays status codes, providing instant feedback on its current operating mode. This allows installers and service engineers to quickly ascertain the boiler’s state, whether it’s in heating mode, domestic hot water mode, or a temporary shutdown period, aiding in rapid troubleshooting.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Vaillant Ecofit Pure 835 Boiler, and we answer them below.


What are the main safety features of the Vaillant Ecofit Pure 835 Boiler?
The boiler includes overheating safety shutdown, built-in frost protection that activates the pump and burner at low temperatures, and a safety feature that stops operation if the condensate drain becomes blocked.

How often should the Vaillant Ecofit Pure 835 Boiler be serviced?
The boiler must be serviced annually by a competent Gas Safe registered engineer to maintain its guarantee and ensure compliance with manufacturer recommendations and regulations.

What type of flue systems are compatible with this boiler?
The Vaillant Ecofit Pure 835 is compatible with released system types C13, C33, C43, and C53, typically referring to various horizontal and vertical concentric flue configurations.

What should I do if I smell gas near the boiler?
Immediately avoid the area, open windows and doors, do not use naked flames or electrical switches, close the emergency control valve, warn others, evacuate the building, and call the gas supply company or Emergency Service Provider from outside.

What are the maximum and minimum heat outputs for heating and domestic hot water?
The maximum heat output for heating is 25 kW, and for domestic hot water, it's 35 kW. The minimum heat input for both heating and hot water is 7.2 kW.

Are there any special considerations for setting the domestic hot water temperature?
Yes, to prevent Legionella, the hot water temperature should ideally be at least 60 °C. However, if water hardness exceeds 3.57 mol/m³, the temperature should not exceed 50 °C to minimize scale deposition.[/faq>
What is the recommended heating system pressure?
The recommended filling pressure for the heating installation is between 0.10 and 0.15 MPa (1.0 and 1.5 bar). If the pressure falls too low, the product may switch off and display a fault code.

Can this boiler be installed in a room with a bath or shower?
Yes, the boiler can be installed in any room. However, if installed in a room with a bath or shower, it must only be placed in zones 2 or 3, complying with I.E.E. Wiring Regulations and Building Regulations.[/faq>
What is the purpose of the high-efficiency pump in the Ecofit Pure 835?
The speed-regulated high-efficiency pump adjusts its output automatically to the heating installation's hydraulic conditions, optimizing performance and energy efficiency. Its operating mode can be adjusted if a low loss header is installed.

What is the NOx class of this boiler?
The Vaillant Ecofit Pure 835 boiler has a NOx class of 6, indicating its compliance with stringent emissions standards.

What should I do if I find fault messages (F.xx) on the display?
Refer to the “Overview of fault codes” section in the manual’s appendix. You can try pressing the reset button up to three times. If the fault persists, contact customer service.

How does the boiler prevent frequent cycling of the burner?
The boiler features an electronic restart lockout, known as the “burner anti-cycling time,” which is activated for a specific period after the burner switches off to prevent energy losses from frequent on/off cycles.