Here we offer the Vaillant Ecofit Pure 830 Boiler manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Vaillant Ecofit Pure 830 Boiler, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5

Vaillant Ecofit Pure 830 Boiler Specifications

Specification Category Parameter Value (VUW 306/6-3 (H-GB))
General Gas Category I2H
Gas Pipe Diameter 1/2 inch
Heating Connections Diameter 3/4 inch
Min. Expansion Relief Valve Pipe 15 mm
Min. Condensate Discharge Pipe 21.5 mm
G20 Gas Supply Pressure 2.0 kPa (20.0 mbar)
CE Number (PIN) CE-0063CP3646
SAP 2009/2012 Annual Efficiency 89.6 %
NOx Class 6
IP Rating IPX4D
Dimensions & Weight Width 390 mm
Depth 295 mm
Height 702 mm
Net Weight 33 kg
Weight (filled with water) 38 kg
Min. Clearance (Top air/flue) 150 mm
Min. Clearance (Rear air/flue) 20 mm
Min. Clearance (Sides) 5 mm
Min. Clearance (Bottom) 500 mm
Output & Input (G20) Maximum Heat Output (Heating) 25 kW
Effective Output Range (P) at 40/30 °C 6.5 to 27.0 kW
Effective Output Range (P) at 50/30 °C 6.3 to 26.5 kW
Effective Output Range (P) at 80/60 °C 6.1 to 25.4 kW
Domestic Hot Water Heat Output (P) 6.0 to 30.0 kW
Maximum Heat Input – Heating (Q max.) 25.5 kW
Minimum Heat Input – Heating (Q min.) 6.1 kW
Maximum Heat Input – Hot Water (Q max.) 30.6 kW
Flue Gas Gas Flow at P max. – Hot Water (G20) 3.2 m³/h
Gas Flow at P max. – Heating Mode (G20) 2.7 m³/h
Flue Gas Mass Rate (Heating P min.) 2.80 g/s
Flue Gas Mass Rate (Heating P max.) 11.5 g/s
Flue Gas Temp (80°C/60°C) P max. 77 ℃
Flue Gas Temp (50°C/30°C) P max. 62 ℃
Flue Gas Temp (Hot Water) 68 ℃
Released System Types C13, C33, C43, C53
Heating Circuit Max. Flow Temperature Adjustment Range 10 to 80 ℃
Maximum Permissible Pressure 0.25 MPa (2.50 bar)
Nominal Water Flow (ΔT = 20 K) 1,094 l/h
Nominal Water Flow (ΔT = 30 K) 729 l/h
Condensate Volume (50/30 °C) 2.55 l/h
ΔP Heating at Nominal Flow (ΔT = 20 K) 0.025 MPa (0.250 bar)
Domestic Hot Water (DHW) Specific Flow Rate (D) (ΔT = 30 K) EN 13203 14.2 l/min
Specific Flow Rate (ΔT = 35 K) 12.2 l/min
Minimum Permissible Pressure 0.03 MPa (0.30 bar)
Maximum Permissible Pressure 1 MPa (10 bar)
Recommended Pressure 0.2 MPa (2.0 bar)
Temperature Range 35 to 60 ℃
Maximum Water Flow Rate 10.0 l/min
Electrical Electrical Connection 230 V / 50 Hz
Max. Electrical Power Consumption 87 W
Standby Electrical Power Consumption 2 W

Vaillant Ecofit Pure 830 Boiler Details

The Vaillant Ecofit Pure 830 is engineered as a highly efficient heat generator for closed heating systems and domestic hot water production. It is explicitly designed for permanent installation within mobile homes located in Great Britain and Ireland, adhering strictly to local gas types. Improper use, such as installation in moving vehicles, is prohibited, ensuring that the unit functions optimally within its intended, fixed environment. This commitment to specific application enhances both safety and performance.

Integrated safety features provide robust protection for the Ecofit Pure 830. In the event of an electrical supply failure, the boiler will cease operation but is designed to automatically resume when power is restored. For potential overheating scenarios, the internal software initiates a shutdown, preventing lockout and requiring a simple reset. This layered approach to safety helps maintain operational integrity and minimizes user intervention in critical situations.

The boiler incorporates an advanced frost protection system to safeguard against freezing. When the boiler water temperature drops below 12°C, the pump activates. Should the temperature continue to fall to 5°C, the burner engages, ensuring the system remains above critical freezing points. Operation ceases once 35°C is reached, efficiently conserving energy. Furthermore, the unit will halt operation if the condensate drain becomes blocked, a common issue in freezing conditions, which can often be resolved by applying warm cloths to the pipe and pressing the reset button.

A sophisticated speed-regulated high-efficiency pump is a core component, intelligently adapting its output to the heating installation's hydraulic conditions. For systems utilizing a low loss header, this pump can be adjusted to a fixed speed via diagnostic parameter d.14, offering greater control and customization. The bypass valve is also adjustable, allowing installers to fine-tune pressure and mitigate noise, with a factory-set mid-position easily modified for specific installation needs.

Maintaining optimal heating water quality is paramount for the Ecofit Pure 830's longevity and performance. Vaillant stipulates that the pH value of the heating water must remain between 6.5 and 8.5 to prevent aluminum corrosion. The manual provides a list of approved additives, including those for cleaning (e.g., Adey MC3+, Fernox F3) and permanent system protection (e.g., Adey MC1+, Fernox F1), as well as specific antifreeze solutions like Adey MC ZERO and Fernox Antifreeze Alphi 11.

Servicing and maintenance are critical for validating the boiler’s warranty and ensuring safe, efficient operation. An annual service by a competent Gas Safe registered engineer is mandatory, utilizing original seals for component replacements. The comprehensive inspection checklist covers everything from gas flow rates and CO₂ content to heat exchanger cleanliness and expansion vessel pressure. These detailed procedures ensure the Ecofit Pure 830 continues to deliver reliable heating and hot water for years.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Vaillant Ecofit Pure 830 Boiler, and we answer them below.


What is the intended use of the Vaillant Ecofit Pure 830 Boiler?
The Vaillant Ecofit Pure 830 is designed as a heat generator for closed heating installations and domestic hot water generation. It is specifically intended for use in mobile homes that are made, transported once, and permanently situated in Great Britain and Ireland, using gas types listed on the data plate. It is not suitable for installation in moving vehicles.

What safety features does the Ecofit Pure 830 have in case of power failure or overheating?
The boiler is equipped with overheating safety, where the software prevents lockout and shuts down before overheating occurs, requiring a simple reset to restart. In the event of an electrical supply failure, the boiler will stop but is designed to resume normal operation once the power supply is restored.

How does the boiler protect itself from freezing temperatures?
The Ecofit Pure 830 features a built-in frost protection device. The pump activates when the boiler water temperature falls below 12°C. If the temperature continues to drop to 5°C, the burner will activate. Both the pump and burner will switch off once the temperature reaches 35°C.

What should I do if the condensate drain becomes blocked, especially due to ice?
If the condensate drain becomes blocked, often due to ice in freezing conditions, the boiler will stop working as a safety feature. To clear an ice blockage, you can apply warm cloths to the external pipe. After clearing, press the reset button on the boiler to restart operation.

What are the minimum clearances required for installing the Ecofit Pure 830?
For installation, minimum clearances are: 150 mm (top air/flue connection) or 20 mm (rear air/flue connection), 150 mm (front), 5 mm (sides), and 500 mm (bottom). These clearances ensure proper ventilation and access for maintenance.

What kind of heating water quality is required for the Ecofit Pure 830, especially regarding pH values?
To prevent material damage, particularly aluminum corrosion, the pH value of the heating water must be maintained between 6.5 and a maximum of 8.5. It's crucial to check and treat the heating water quality before filling or topping up the system.

How do I access the installer level on the boiler and what is its purpose?
The installer level is accessed by pressing the 'i' button simultaneously. Once accessed, you enter code '17' to gain entry. This level allows competent persons to view diagnostic codes, fault memory, and perform specific check programmes (P.00, P.01, P.02, P.06) for commissioning, inspection, and maintenance.

What is the recommended filling pressure for the heating installation?
The recommended filling pressure for the heating installation is between 0.10 and 0.15 MPa (1.0 and 1.5 bar). If the pressure falls below 0.03 MPa (0.3 bar), the product will switch off and display fault F.22, indicating a water deficiency.

How often should the Vaillant Ecofit Pure 830 Boiler be serviced to maintain its warranty?
To maintain the warranty, the boiler must be serviced annually by a competent person holding the required qualifications. The service details should be recorded on the Benchmark Service and Interim Boiler Work Record. Failure to comply with these annual servicing requirements will invalidate the warranty.

What is the meaning of fault code F.22 and how can it be resolved?
Fault code F.22 indicates a safety shutdown due to water deficiency in the boiler. This means there is no or insufficient water in the product. To resolve, you need to top up the water in the heating installation until the recommended filling pressure is reached, and then restart the product.