Vaillant EcoTEC Plus 840 Boiler Instruction Manual

Manual Vaillant EcoTEC Plus 840 Boiler Instruction Manual

Vaillant EcoTEC Plus 840 Boiler Instruction Manual

5/5 (1👤)
📕 Manual PDF 📄 24 Pages
★Rate It★

How many stars do you give this manual?

Vaillant EcoTEC Plus 840 Boiler

Full Screen

Vaillant EcoTEC Plus 840 Boiler

Full Screen

Vaillant EcoTEC Plus 840 Instructions

Here we offer the Vaillant EcoTEC Plus 840 Boiler manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Vaillant EcoTEC Plus 840 Boiler, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Imagen 6
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5
Miniatura 6

Vaillant EcoTEC Plus 840 Boiler Specifications

Feature Specification
Product Article Number 0010036018
Gas Council Number 47-044-95
Designated Country GB, IE
Permitted Gas Boiler Category II2H3P (Natural Gas, Propane)
CE PIN 0063CU3910
UKCA PIN 0063CU3910
Dimensions (Height x Width x Depth) 720 mm x 440 mm x 386 mm
Empty Weight 40 kg
Weight Ready for Operation (filled) 48 kg
Gas Connection (boiler side) 15 mm
Heating Flow/Return Connections (boiler side) G 3/4 ″
Domestic Hot/Cold Water Connections (boiler side) G 3/4 ″
Expansion Relief Valve Connection 15 mm
Condensate Discharge Hose Connection 19 mm
Air/Flue Pipe Connection 60/100 mm
Capacity of Heating Expansion Vessel 10 l
Pre-charge Pressure of Heating Expansion Vessel 70 kPa (700 mbar)
Min. Flue Gas Temperature 35 ℃
Max. Flue Gas Temperature 85 ℃
Approved Gas Boiler Types C13, C33, C43, C53
NOx Class 6
Gas Connection Pressure (G20 Natural Gas) 2.0 kPa (20.0 mbar)
NOx Emission (G20) 26.30 mg/kWh
30% Efficiency (G20) 109.2 %
Nominal Heat Output Range (40/30 °C) 5.2 to 32.9 kW
Nominal Heat Output Range (80/60 °C) 4.5 to 29.8 kW
Max. Heat Output for Domestic Hot Water 45.3 kW
Max. Flow Temperature 85 ℃
Flow Temperature Adjustment Range 30 to 80 ℃ (Factory: 75 °C)
Permissible Operating Pressure (Heating) 0.25 MPa (2.50 bar)
Approx. Condensate Rate (50/30 °C heating mode) 3.1 l/h
Start-up Flow Rate (DHW) 2.0 l/min
Specific Flow Rate D (ΔT = 30 K) 19.0 l/min
Permissible Operating Pressure (DHW) 0.95 MPa (9.50 bar)
Domestic Hot Water Temperature Adjustment Range 35 to 65 ℃
Flow Rate Limiter (DHW) 14.0 l/min
Electrical Rated Voltage 230 V~
Mains Frequency 50 Hz
Built-in Fuse (slow-blow) 4 A
Max. Power Consumption (Heating Mode) 98.5 W
Max. Power Consumption (DHW Mode) 134 W
Electrical Standby Energy Consumption < 2 W
IP Rating IPX5D

Vaillant EcoTEC Plus 840 Boiler Details

The Vaillant EcoTEC Plus 840 Boiler features an intuitive operating concept, incorporating color-lit control elements that dim after inactivity to save energy. Its clear display shows various symbols, indicating burner modulation rate, system pressure, heating and DHW status, comfort mode activation, and maintenance requirements. Important product identification, such as the serial number, can be found on both the front panel underside and the data plate, which also details production and article numbers for easy reference.

This boiler proudly carries CE and UKCA markings, confirming its compliance with relevant European and UK directives. Vaillant's membership in the Hot Water Association and adherence to the Benchmark Scheme underscores the product's commitment to quality, safe installation, and proper servicing standards. Users are encouraged to ensure the installer completes the Benchmark Checklist, which is crucial for upholding the comprehensive two-year guarantee and any potential extended warranties.

Beyond its core functionality, the EcoTEC Plus 840 offers diverse operational modes. Users can effortlessly set desired flow temperatures for heating and domestic hot water. The boiler supports a "summer mode" for heating deactivation and a "comfort mode" for rapid hot water availability. When connected with a sensoROOM pure (VRT 50/2) control, users gain advanced management over heating time periods and overall heating system control directly from the room thermostat.

Maintaining the EcoTEC Plus 840 is straightforward; the casing requires only a damp cloth and solvent-free soap. Annual inspections by a qualified competent person are vital for long-term reliability. The boiler provides clear maintenance messages, including alerts for low heating system pressure or when condensate discharge pipe checks are due. In the event of faults (F.XXX) or limp home mode (N.XXX) codes, the manual provides troubleshooting guidance, advising when professional assistance is necessary.

At the heart of its efficiency lies Sitherm Pro™ technology, an intelligent combustion regulation system that adaptively optimizes performance. This advanced feature eliminates the need for manual gas-air ratio adjustments within the same gas family. While the boiler provides approximate energy consumption data based on algorithms, it's explicitly noted that these figures are for informational purposes and not suitable for billing comparisons, reflecting varying installation conditions and user behavior.

Designed for internal installation, the boiler incorporates robust safety devices. These include protection against electrical supply failure, automatic shutdown mechanisms for overheating, and an integrated frost protection system that activates the pump and burner at low temperatures. A safety feature also stops the boiler if the condensate drain becomes blocked, often due to freezing. Proper water treatment, including monitoring hardness and pH, is essential to prevent material damage and ensure optimal performance.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Vaillant EcoTEC Plus 840 Boiler, and we answer them below.


What is the product article number for the Vaillant EcoTEC Plus 840 Boiler?
The product article number for the Vaillant EcoTEC Plus 840 Boiler (VUW 30/40CS/1-5 (N-GB)) is 0010036018.

What is the recommended operating pressure for the heating system?
A filling pressure of at least 1 bar (0.1 MPa) is recommended, with a maximum of 2.5 bar (0.25 MPa). If the pressure falls below 0.8 bar (0.08 MPa), the heating water needs to be topped up.

How do I adjust the domestic hot water temperature?
From the basic display, press the DHW temperature setting button, then use the scrollbar to set your desired temperature between 35 to 65 °C.

How do I temporarily switch off the heating mode (summer mode)?
If a sensoROOM pure control is not connected, press and hold the heating mode button for at least three seconds. If a sensoROOM pure control is connected, set the lowest target room temperature (e.g., 15 °C) on that control.

What does a flashing system pressure symbol mean on the display?
A flashing system pressure symbol indicates that the filling pressure in your heating system is outside the permitted range. You should check the pressure and add heating water if necessary.

How often should the EcoTEC Plus 840 boiler be serviced?
An annual inspection by a competent person is required to ensure the boiler's permanent readiness, safe operation, reliability, and long working life. An annual service is also necessary for the second year of the guarantee to be valid.

What should I do if I smell gas?
If you smell gas, immediately avoid the affected rooms, open doors and windows for ventilation, do not use naked flames or electrical switches, close the emergency control valve, warn other occupants, evacuate the building, and alert emergency services (police, fire brigade, gas supply company) from a safe location outside.

What does 'Sitherm Pro™ technology' mean for the boiler?
Sitherm Pro™ technology is an intelligent combustion regulation system based on adaptive Siemens combustion optimization. This means the boiler automatically manages the gas-air ratio, eliminating the need for manual adjustment within the same gas family.

What kind of frost protection does the boiler have?
The boiler has a built-in frost protection device. With gas and electricity on, the pump activates when boiler water falls below 12 °C. The burner will activate if the boiler temperature does not reach 15 °C after 30 minutes, or if it drops to 5 °C, switching off at 35 °C.

Can the Vaillant EcoTEC Plus 840 Boiler be installed outdoors?
No, the Vaillant EcoTEC Plus 840 Boiler is not suitable for outdoor installation. It can be installed in any indoor room, but if installed in a bathroom or shower room, it must adhere to specific zones (2 or 3) according to I.E.E. Wiring Regulations and Building Regulations.

What is the significance of the Benchmark scheme for this boiler?
Vaillant is a licensed member of the Benchmark Scheme, which aims to improve installation and commissioning standards. Installers are required to complete a Benchmark Checklist to demonstrate compliance with Building Regulations, which is essential for warranty validation and should be kept by the customer.

What should I use to clean the boiler casing?
You should clean the boiler casing with a damp cloth and a little solvent-free soap. Do not use sprays, scouring agents, detergents, solvents, or cleaning agents that contain chlorine, as these can cause damage.

Where can I find the serial number of my boiler?
The serial numbers are located on the underside of the front panel and also on the data plate. The 3rd to 6th digits of the serial number indicate the production date (year/week).

What are the requirements for heating water quality?
Heating water must be of sufficient quality. The pH value should be between 8.2 and 10.0 at 25 °C. If water contains sedimentary materials or magnetite, the system requires desludging or cleaning, followed by suitable corrosion-inhibition measures. Water hardness guidelines also apply based on system volume and heat output.

What do fault codes like F.022 or F.028 indicate?
Fault code F.022 typically indicates no or insufficient water in the product, or that the water pressure is too low. Fault code F.028 signifies that the flame signal was not detected during the ignition phase, often occurring after five unsuccessful ignition attempts, possibly due to gas supply issues.

Related product manuals