Weil-Mclain Ultra 399 Serie 4 Boiler Instruction Manual

Manual Weil-Mclain Ultra 399 Serie 4 Boiler Instruction Manual

Weil-Mclain Ultra 399 Serie 4 Boiler Instruction Manual

5/5 (1👤)
📕 Manual PDF 📄 12 Pages
★Rate It★

How many stars do you give this manual?

Weil-Mclain Ultra 399 Serie 4 Boiler

Full Screen

Weil-Mclain Ultra 399 Serie 4 Boiler

Full Screen

Weil-Mclain Ultra 399 Serie 4 Boiler

Full Screen

Weil-Mclain Ultra 399 Serie 4 Boiler

Full Screen

Weil-Mclain Ultra 399 Serie 4 Instructions

Here we offer the Weil-Mclain Ultra 399 Serie 4 Boiler manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Weil-Mclain Ultra 399 Serie 4 Boiler, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Miniatura 1
Miniatura 2
Miniatura 3

Weil-Mclain Ultra 399 Serie 4 Boiler Specifications

Specification Weil-Mclain Ultra 399 Serie 4
Model ULTRA 399
Boiler Type Gas-fired Water Boiler, Condensing
Series 4
Input (MBH) 399
Output (MBH) 380
AFUE Rating 95%
Thermal Efficiency 95%
Minimum Vent Size (PVC/CPVC/PP) 4 inches
Supply/Return Connection 1¼" NPT
Gas Connection ¾" NPT
Electrical Requirements 120 V / 60 Hz / 1 Phase
Maximum Operating Water Temperature 180°F
Maximum Operating Pressure 30 PSI
Height 45.1 inches
Width 22.8 inches
Depth 23.3 inches
Shipping Weight 210 lbs
Heat Exchanger Material Cast Aluminum Block
Burner Type Woven Steel Fiber Mesh
Ignition System Direct Spark Ignition
Blower Type Variable Speed Blower Assembly
Gas Valve Negative Pressure Regulated
Boiler Circulator (Standard) Taco 0013 (1¼" & 1½" Flanges)
Control Module U-Control Module (3.5" LCD display)

Weil-Mclain Ultra 399 Serie 4 Boiler Details

The Weil-Mclain Ultra 399 Serie 4 boiler is designed for ultra-efficient condensing operation, featuring advanced controls and robust construction. Its user-friendly information manual emphasizes critical safety precautions, outlining potential hazards with clear definitions like DANGERWARNINGCAUTION, and NOTICE to ensure user and property protection.

A significant focus of the manual is preventing combustion air contamination. It explicitly lists numerous household, hobby, and industrial products containing fluorine or chlorine compounds, which can form strong acids within the boiler. Operating the boiler in areas like laundry rooms, swimming pools, or auto body shops without proper precautions is highly discouraged due to the risk of severe damage and flue gas spillage.

Proper boiler service and maintenance are paramount for reliability and safety. The manual stresses that installation and annual startup must be performed by a qualified service technician. Users are advised to disconnect electrical supply and allow the boiler to cool before any maintenance to prevent electric shock or severe burns.

The U-Control Module is a central feature, equipped with a 3.5" LCD display. This advanced control system offers three boiler priorities, multiple preset system configurations, and multi-boiler functionality. It manages ignition, high limit, and modulating temperature control, incorporating important low water protection and outdoor reset capabilities.

Daily checks include verifying the boiler area for combustible materials and air contaminants, ensuring air openings are clear, checking the pressure/temperature gauge (should not exceed 25 psig), and confirming the boiler front door is securely fastened. This door seal is crucial to prevent the boiler from drawing air from inside the room, especially when other appliances are present.

Monthly maintenance involves inspecting vent and air piping for blockages or leaks, and checking the relief valve for weeping. The condensate drain system also requires attention; users should verify it's unobstructed and fill the condensate trap if flue gas is escaping, indicating a dry trap. Automatic air vents, if installed, also need a quick check for proper operation.

Every six months, a more thorough inspection of boiler piping for gas and water leaks is required. The relief valve should also be operated to ensure it functions freely and does not weep afterward. For the end of the heating season, the manual provides instructions for shutting down the gas supply, but cautions against draining the system unless freezing temperatures are a risk, or if it contains antifreeze.

The boiler's construction features a cast aluminum block and a woven steel fiber mesh burner (for the 399 model), contributing to its efficiency and durability. Standard equipment includes direct spark ignition, a variable speed blower, a venturi mixing system with an air silencer, and various temperature sensors for precise control.

Beyond the core boiler, the complete jacket assembly provides practical benefits with a fully removable front, adjustable boiler legs, and an integrated condensate trap with a drain tee. An on/off power switch and a propane conversion orifice (for most models) are also part of the standard package, enhancing installation flexibility and user convenience.

Optional equipment extends the boiler's functionality and installation options. These include a wall mounting kit for space-saving installations, a low water cutoff (LWCO) with harness and test button for added safety, and a concentric vent kit for simplified venting. A condensate neutralizer kit helps manage acidic condensate, and an Ultra Easy-Up Manifold assists with plumbing connections.

For optimal system longevity, the manual advises against using petroleum-based cleaning or sealing compounds and "homemade cures" in the boiler system, which can damage gaskets and seals. It also warns against continual fresh makeup water, as mineral build-up and oxygen addition can significantly reduce boiler life and cause corrosion or heat exchanger failure.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Weil-Mclain Ultra 399 Serie 4 Boiler, and we answer them below.


What are the main safety precautions before operating this boiler?
Before operation, ensure all warnings and hazard definitions in the manual are understood. Do not store flammable materials nearby. In case of gas smell, follow emergency procedures. Always ensure proper installation and servicing by a qualified technician.

Why is it important to prevent combustion air contamination?
Contaminated combustion air, from products containing fluorine or chlorine, can form strong acids within the boiler. This acid can severely damage the boiler's components, leading to potential flue gas spillage or boiler water leakage and presenting a significant safety hazard.

How often should the Weil-Mclain Ultra 399 Serie 4 Boiler be serviced?
The boiler must be inspected, serviced, and started annually at the beginning of the heating season by a qualified service technician to ensure reliable operation and system longevity. Regular owner maintenance (daily, monthly, periodically, every 6 months) is also required as outlined in the manual.

What should I do if I smell gas near the boiler?
Immediately leave the building. Do not try to light any appliance, touch electrical switches, or use any phone inside. Call your gas supplier from a phone outside the structure. If you cannot reach your supplier, call the fire department.

Can I use automotive antifreeze in my boiler system?
No, never use automotive or standard glycol antifreeze. Only use freeze-protection fluids specifically made for hydronic systems and follow all guidelines provided by the antifreeze manufacturer. Thoroughly clean and flush any system that previously used glycol before installing a new boiler.

How do I check the condensate drain system?
While the boiler is running, check the discharge end of the condensate drain tubing and the open top of the condensate tee for escaping flue gas. If gas is present, the trap is dry and needs to be filled with water. Also, verify the line is unobstructed by slowly pouring water into the tee.

What is the purpose of the U-Control display?
The U-Control display is a 3.5" LCD screen that serves as the boiler's primary interface. It provides system information, allows for configuration of boiler priorities, monitors various sensors, controls circulators, manages ignition, and displays alarm conditions.

What should I do if the pressure/temperature gauge shows above 25 psig?
If the pressure reading on the gauge frequently exceeds 25 psig, it may indicate a problem with the expansion tank or other system components. You should immediately contact a qualified service technician to inspect the boiler and system.

Is it safe to operate the boiler if any part has been under water?
No, do not use the boiler if any part has been under water. Immediately call a qualified service technician to inspect the boiler and replace any part of the control system and any gas control that has been submerged.

What are the daily maintenance checks recommended for this boiler?
Daily maintenance includes checking the boiler area for combustibles or contaminants, verifying that combustion and ventilation air openings are clear, inspecting the pressure/temperature gauge, and ensuring the boiler front door is securely fastened and sealed.

How do I ensure the boiler front door is secure?
Visually inspect the boiler front door to ensure it is sealed all around its perimeter and that the two lower thumb screws are tight. The door must be securely fastened to prevent the boiler from drawing air from inside the boiler room, especially if other appliances are present.

Why should I avoid continual fresh makeup water in the boiler system?
Continual fresh makeup water introduces minerals that can build up in the heat exchanger, reducing heat transfer and causing overheating and failure. It also introduces oxygen, which can cause internal corrosion in system components, thereby reducing the boiler's lifespan. All leaks must be repaired promptly.