Danfoss RX1 Radio-Frequency Receiver Instruction Manual

Manual Danfoss RX1 Radio-Frequency Receiver Instruction Manual

Danfoss RX1 Radio-Frequency Receiver Instruction Manual

5/5 (1👤)
📕 Manual PDF 📄 11 Pages
★Rate It★

How many stars do you give this manual?

Danfoss RX1 Radio-Frequency Receiver

Full Screen

Danfoss RX1 Receiver Instructions

Here we offer the Danfoss RX1 Radio-Frequency Receiver manual completely free and in English. We have cataloged this manual in the Radio-Frequency Receivers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Danfoss RX1 Radio-Frequency Receiver, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5

Danfoss RX1 Radio-Frequency Receiver Specifications

Feature Specification
Product Type Electronic radio-frequency receiver module, 1-channel
Number of Channels 1 (CH1)
Supply Voltage 230 Vac ± 15%, 50 Hz
Construction Standards BS EN 60730-2-1, EN 300-220-1
Maximum Ambient Temperature 45°C
Switch Type 1 x SPDT, type 1B
Switch Rating 264 Vac, 3 (1) A (total current)
IP Rating IP 40
Control Pollution Situation Degree 2
Maximum Range 30 metres
Operating Frequency 433.92 MHz
Software Classification Class A
Rated Impulse Voltage 2.5 kV
Ball Pressure Test 75°C
Wiring Terminals N, L, 1, 2, 3, 4 (COM, Zone 1 ON, Zone 1 OFF)
Mains Voltage Wiring Link terminals L and 2
Compatible Thermostats TP5000-RF, TP5.2-RF, TP5E-RF, RT51-RF, RT52-RF, RT1-RF, RT2-RF, TP7000-RF, TP75-RF, WP75-RF, RET B-RF, CET B-RF
Compliance EC Electromagnetic Compatibility Directive and Low Voltage Directive (CE marked)
Document Reference 32 No 30622 Issue 05 07/07

Danfoss RX1 Receiver Details

The Danfoss RX1 is the single-channel model in the RX range of electronic radio-frequency receivers. The range also includes the RX2, RX2C, RX3, RX3B and RX3B-VF. The RX1 is the receiving end of a wireless heating control system: it takes signals from a compatible Danfoss RF room thermostat and switches a boiler, zone valve or other heating load. Because the thermostat and the switching hardware are separate, you can put the thermostat in the best spot to sense temperature without running cable back to the boiler.

The manual sorts compatible thermostats into three groups. Each group uses a different method to start pairing. Type A covers the TP5000-RF, TP5.2-RF, TP5E-RF, RT51-RF, RT52-RF, RT1-RF and RT2-RF. Type B covers the TP7000-RF, TP75-RF and WP75-RF. Type C covers the RET B-RF and CET B-RF. On Type C units, the LEARN button sits under the setting dial.

Pairing, which the manual calls the Learn process, has two steps. First, put the thermostat into transmit mode. On Type A, press and hold the minus and plus buttons together for 3 seconds. On Type B, hold the LEARN button for 3 seconds. On Type C, take off the dial and hold the LEARN button underneath for 3 seconds. Don't refit the knob until pairing has finished. Once triggered, the thermostat transmits continuously for 5 minutes.

Second, while the thermostat is transmitting, press and hold PROG and CH1 on the RX1 together for 3 seconds. Keep holding until the green light flashes, which confirms the receiver has learned that thermostat. On multi-channel models you have to wait 5 minutes before pairing each extra thermostat. The RX1 has only one channel, so you pair it once.

The front panel has three indicators. The zone status LED lights when the zone is calling for heat ("ON"). The receiver status LED flashes whenever the unit receives a radio signal, which helps you check the link during commissioning. The programming buttons are only meant to be used during setup.

A key safety feature is the Emergency "ON" button. If radio contact with the thermostat fails, for example because of interference or flat thermostat batteries, you can press it to turn the heating on manually. When communication comes back, the receiver returns to AUTO by itself and the thermostat takes over again, so you don't need to reset anything.

The output relay is a changeover contact with three terminals: common (COM), Zone 1 ON and Zone 1 OFF. This means the RX1 can drive both normally-open and normally-closed devices, such as spring-return zone valves, boiler demand inputs or pump circuits. Because the contact is voltage-free, it also suits low-voltage boiler interfaces. For a mains-voltage switched output, the manual says to link terminals L and 2.

The installation guide comes in English, French, German, Spanish, Danish, Dutch, Greek, Polish, Lithuanian and Italian. The wiring diagrams use a shared multilingual legend for terms like Electronics, COM, Zone, Boiler, CH (central heating) and HW (hot water), so installers in different countries can follow the same drawings.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Danfoss RX1 Radio-Frequency Receiver, and we answer them below.


Which thermostats work with the Danfoss RX1?
The RX1 works with the TP5000-RF, TP5.2-RF, TP5E-RF, RT51-RF, RT52-RF, RT1-RF, RT2-RF, TP7000-RF, TP75-RF, WP75-RF, RET B-RF and CET B-RF, all transmitting at 433.92 MHz.

How do I pair a thermostat with the RX1?
Put the thermostat into Learn mode using the method for its type (A, B or C). Then press and hold PROG and CH1 on the RX1 for 3 seconds until the green light flashes.

How do I start Learn mode on a Type A thermostat?
Press and hold the minus and plus buttons together for 3 seconds. The thermostat then transmits continuously for 5 minutes.

Where is the LEARN button on RET B-RF and CET B-RF thermostats?
These Type C thermostats have the LEARN button under the setting dial. Take off the dial, hold the button for 3 seconds, and don't refit the knob until pairing has finished.

What is the maximum wireless range of the RX1?
The maximum range between the thermostat and the receiver is 30 metres. Walls and other obstacles can shorten the range you actually get.

What should I do if the receiver loses communication with the thermostat?
Press the Emergency "ON" button on the receiver to turn the heating on. When communication comes back, the unit returns to AUTO by itself.

What do the LEDs on the RX1 mean?
The zone status LED lights when the zone is ON (calling for heat). The receiver status LED flashes when the unit receives a radio signal from the thermostat.

How do I wire the RX1 for a mains voltage application?
Link terminals L and 2 so the relay switches mains voltage. Then connect the load to the Zone 1 ON or Zone 1 OFF terminal as required.

What load can the RX1 relay switch?
The single SPDT relay is rated at 264 Vac, 3 (1) A total current: 3 A for resistive loads and 1 A for inductive loads.

Can the RX1 be installed in a damp or outdoor location?
No. The RX1 is rated IP 40 for a maximum ambient temperature of 45°C, so it should be installed indoors in a dry place.

What power supply does the RX1 need?
The receiver runs on 230 Vac ± 15%, 50 Hz, connected to the N and L terminals.