Vaillant EcoTEC Plus 824 Boiler Instruction Manual

Manual Vaillant EcoTEC Plus 824 Boiler Instruction Manual

Vaillant EcoTEC Plus 824 Boiler Instruction Manual

5/5 (1👤)
📕 Manual PDF 📄 16 Pages
★Rate It★

How many stars do you give this manual?

Vaillant EcoTEC Plus 824 Boiler

Full Screen

Vaillant EcoTEC Plus 824 Boiler

Full Screen

Vaillant EcoTEC Plus 824 Instructions

Here we offer the Vaillant EcoTEC Plus 824 Boiler manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Vaillant EcoTEC Plus 824 Boiler, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4

Vaillant EcoTEC Plus 824 Boiler Specifications

Specification Value
CH Heat Output (80°C/60°C return) 6.7 – 19.0 kW
CH Heat Output (60°C/40°C return) 6.9 – 19.6 kW
CH Heat Output (50°C/30°C return) 7.1 – 20.2 kW
CH Heat Output (40°C/30°C return) 7.2 – 20.6 kW
Maximum DHW Output 23.0 kW
Maximum Output for Heating 19 kW
Minimum Output 6.7 kW
Category II2H3P
SEDBUK Band A
SAP Seasonal Efficiency 91.1 %
Inlet Gas Working Pressure (G20, Natural Gas) 20 mbar
Inlet Gas Working Pressure (G31, Propane) 37 mbar
Connected Load (G20) 2.5 m³/h
Connected Load (G31) 1.82 kg/h
Exhaust Mass Rate (Min Thermal Load) 3.2 g/s
Exhaust Mass Rate (Max Thermal Load) 10.7 g/s
Exhaust Temperature (Min Thermal Load) 40 °C
Exhaust Temperature (Max Thermal Load) 74 °C
NOx Class 5
Protection Class IP X4D
Max. Flow Temperature 85 °C
Adjustable Flow Temperature Range 30 – 85 °C (Default: max. 75 °C)
Maximum CH System Pressure 3.0 bar
Circulation Water Volume (ΔT=20 K) 817 l/h
Approx. Condensation Volume (50°C/30°C) 1.8 l/h
Pump Delivery Height 250 mbar
Minimum DHW Flow Rate 1.5 l/min
DHW Flow Rate (ΔT=35 K Rise) 9.4 l/min
DHW Flow Rate (Factory Set ΔT=42 K) 7.9 l/min
Permitted DHW Overpressure 10 bar
Mains Water Pressure Required (Max Flow) 0.5 bar
Mains Water Pressure Required (Min Flow) 0.15 bar
Hot Water Discharge Temperature Range 35 – 65 °C
Exhaust Flue 60/100 mm
Flue Categories C13, C33, C43, C53, C83, B23, B33
10L Expansion Vessel Pre-charge Pressure 0.75 bar
Connections Heating Flow/Return 22 mm
Gas Inlet Connection 15 mm
Pressure Relief Discharge Pipework (Min.) 15 mm
Condensate Drain (Min. Internal Drain) 19 mm
Dimensions (H x W x D) 720 x 440 x 335 mm
Weight (Boiler Only) 35 kg
Primary Water Content 1.9 l
Electrical Supply Voltage 230/50 V~/Hz
Internal Fuse (Slow) Main Voltage 2 A
Power Input 110 W
Gas Council Number 47-044-31

Vaillant EcoTEC Plus 824 Boiler Details

The Vaillant EcoTEC Plus 824 is a compact, wall-mounted condensing combination boiler engineered to provide both central heating and domestic hot water directly and efficiently. It operates automatically, intelligently adjusting its performance to meet the demands for heating and hot water in the most economical way possible, minimizing energy waste.

This model features an advanced multifunctional digital display system. This intuitive interface provides the user with crucial operational information, including the current heating flow temperature, system pressure, and various status or error codes, ensuring transparency and ease of monitoring. An "i" (information) button allows users to quickly access these detailed status displays.

A notable convenience feature is the Warmstart function, which ensures immediate hot water at the desired temperature. It achieves this by maintaining the hot water heat exchanger at a pre-selected temperature, ready for instantaneous delivery. Users can easily adjust the domestic hot water temperature within a range of 35°C to 65°C using a dedicated control knob.

For central heating, the boiler offers flexible temperature control for radiators, with settings ranging from a gentle heat suitable for spring/autumn to higher temperatures for colder winter conditions. While the default maximum flow temperature is 75°C, a qualified engineer can adjust it higher if required by the system. The boiler also supports a convenient summer operation mode, allowing users to switch off heating while maintaining hot water supply.

The EcoTEC Plus 824 is equipped with vital protective features, including an integral frost protection function that activates if the boiler's internal water temperature drops below 5°C. This helps prevent damage to the boiler itself, provided it remains powered and switched on. Additionally, an anti-cycling economiser control prevents inefficient short bursts of operation in heating mode.

Designed for longevity and reliability, the boiler includes an Automatic Pump Spin control (APS). This feature periodically runs the internal circulating pump and operates the diverter valve (if fitted) every 23 hours. This intelligent mechanism helps prevent component seizure during periods of inactivity, contributing to the boiler's long-term operational stability. Installation is flexible, accommodating various flue system options for diverse property layouts.

Further enhancing its appeal, the EcoTEC Plus 824 comes with a two-year guarantee, underscoring Vaillant's commitment to quality. However, it is important to note that the second year of this guarantee is contingent upon the boiler receiving an annual service from a competent, qualified installer. This emphasizes the importance of regular maintenance for optimal performance and safety.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Vaillant EcoTEC Plus 824 Boiler, and we answer them below.


My Vaillant EcoTEC Plus 824 boiler is not operating. What should I check first?
First, verify the gas and water supplies are open, the electrical supply is switched ON, and the main ON/OFF control is set to "I". Check the system water pressure (should be in the dark grey zone, 1.0-2.0 bar) and ensure all external heating controls are calling for heat.

What should I do if I smell gas or suspect a gas leak?
Immediately stop all activities that could create a spark or flame. Do NOT switch lights or any electrical devices ON or OFF. Do NOT use a telephone in the hazardous area. Turn off the main gas supply at the meter, open windows and doors, warn other residents, and evacuate. Contact your gas supplier or a qualified professional from outside the property.

How do I activate the Warmstart function for instant hot water?
To activate Warmstart, briefly turn the hot water temperature control knob all the way clockwise (to position 'a'). Then, select your desired hot water temperature. The Warmstart symbol will flash on the display, indicating it's active and pre-heating water for immediate use.

What does the 'S.4' status display mean on my boiler?
The "S.4" status code indicates that the burner is ignited and the boiler is currently in normal heating operation. This is a common display during active central heating.

What should I do if the boiler displays a fault code like 'F.22', 'F.23', or 'F.24'?
These fault codes (F.22, F.23, F.24) signify low system water pressure or a lack of water. You must refill the heating system with water until the pressure gauge indicates a pressure between 1.0 and 2.0 bar (the dark grey zone) before attempting to restart the boiler.

My boiler shows 'F.28' or 'F.29' and won't ignite. How can I resolve this?
"F.28" or "F.29" indicate ignition problems. To attempt a reset, press and hold the "Reset" button for one second. The boiler will then try to ignite again. If the issue persists after three reset attempts, contact your installer or Vaillant Service Solutions.

How do I switch off the central heating during summer without affecting hot water?
To switch off the central heating for summer operation while maintaining domestic hot water supply, simply turn the maximum radiator temperature control knob all the way to the left (minimum setting).

What is the recommended system pressure for the heating system?
When the heating system is cold, the pressure gauge indicator should ideally be within the dark grey zone, typically between 1.0 and 2.0 bar. If the indicator falls into the light grey area (below 0.8 bar), the system needs to be refilled with water.

Does the Vaillant EcoTEC Plus 824 have frost protection?
Yes, the boiler includes a frost protection function. If the internal heating water temperature drops below 5°C, the boiler will automatically activate and heat the boiler circuit to approximately 30°C. This function is active only when the main switch is ON and the boiler is connected to the electrical supply.

How often should the Vaillant EcoTEC Plus 824 boiler be serviced?
An annual inspection by a competent person is recommended. Full maintenance, which includes cleaning and any necessary adjustments, should be carried out at regular intervals, but not less frequently than every five years, based on the findings of the annual inspections.

Can I use thermostatic radiator valves (TRVs) with this boiler?
Yes, the Vaillant EcoTEC Plus 824 is designed to work effectively with thermostatic radiator valves. It features a built-in automatic by-pass valve, which means you do not need to install an additional system by-pass when using TRVs.

What is the purpose of the anti-cycling 'economiser' control?
The anti-cycling 'economiser' control is an integrated feature designed to prevent the boiler from 'short cycling' – turning ON and OFF frequently for brief periods. This control mechanism ensures more efficient operation in central heating mode by introducing a preset delay before the boiler reignites, thereby reducing energy wastage. Hot water operation is unaffected by this control.

Where can I find the data badge for the EcoTEC Plus 824 boiler?
The data badge, which contains important identification information for your boiler, is factory-attached to the bottom underside of the appliance.

What are the dimensions and weight of the Vaillant EcoTEC Plus 824 boiler?
The dimensions of the EcoTEC Plus 824 are 720 mm (Height) x 440 mm (Width) x 335 mm (Depth). The boiler itself weighs 35 kg.

Related product manuals

Go up