Here we offer the Vaillant EcoTEC Plus 615 Boiler manual completely free and in English. We have cataloged this manual in the Boilers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Vaillant EcoTEC Plus 615 Boiler, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5

Vaillant EcoTEC Plus 615 Boiler Specifications

Feature Specification
Product Article Number 0010036010
Gas Council Number 41-694-46
Designated Country GB, IE
Boiler Category II2H3P
CE PIN 0063CU3910
UKCA PIN 0063CU3910
Gas Connection (Boiler Side) 15 mm
Heating Flow/Return Connections (Boiler Side) G 3/4 ″
Domestic Hot/Cold Water Connections (Boiler Side) Not applicable (System Boiler)
Expansion Relief Valve Connection 15 mm
Condensate Discharge Hose Connection 19 mm
Air/Flue Pipe Connection 60/100 mm
Heating Expansion Vessel Capacity 10 l
Heating Expansion Vessel Pre-charge Pressure 70 kPa (700 mbar)
Min. Flue Gas Temperature 35 ℃
Max. Flue Gas Temperature 85 ℃
Approved Gas Boiler Types C13, C33, C43, C53
NOx Class 6
Weight with Packaging (incl. accessories) 37 kg
Empty Weight of Product 32 kg
Weight Ready for Operation (filled) 37 kg
Gas Connection Pressure, G20 Natural Gas 2.0 kPa (20.0 mbar)
NOx Emission, G20 (EN 15502-2-1) 35.00 mg/kWh
30% Efficiency, G20 108.5 %
Nominal Heat Output Range at 80/60 °C (G20) 2.5 to 14.8 kW
Nominal Heat Input Range for Heating (Hi) (G20) 2.7 to 15.3 kW
Heating Adjustment Range (G20) 2.7 to 15.3 kW
Max. Heat Output for DHW (G20, for external cylinder) 22.6 kW
Gas Connection Pressure, G31 LPG 3.7 kPa (37.0 mbar)
Nominal Heat Output Range at 80/60 °C (G31) 5.0 to 14.8 kW
Nominal Heat Input Range for Heating (Hi) (G31) 5.2 to 15.3 kW
Heating Adjustment Range (G31) 5.2 to 15.3 kW
Max. Heat Output for DHW (G31, for external cylinder) 22.2 kW
Max. Flow Temperature 85 ℃
Flow Temperature Adjustment Range (Factory: 75°C) 30 to 80 ℃
Permissible Operating Pressure (Heating) 0.25 MPa (2.50 bar)
Nominal Circulation Water Volume (ΔT = 20 K, 80/60 °C) 659 l/h
Approx. Condensate Rate (50/30 °C heating mode) 1.5 l/h
Remaining Pump Head at Nominal Circulation Water Volume 0.025 MPa (0.250 bar)
Rated Voltage 230 V~
Mains Frequency 50 Hz
Permissible Connected Voltage 190 to 253 V~
Built-in Fuse (slow-blow) 4 A
Max. Power Consumption in Heating Mode 66.3 W
Max. Power Consumption in Domestic Hot Water Mode (for external cylinder) 96 W
Electrical Standby Energy Consumption < 2 W
IP Rating IPX5D

Vaillant EcoTEC Plus 615 Boiler Details

The Vaillant EcoTEC Plus 615 is a highly efficient condensing system boiler, designed to provide reliable central heating for homes. As a 'VU' model, it focuses solely on heating, requiring a separate hot water cylinder for domestic hot water (DHW) generation. This model incorporates Vaillant's advanced Sitherm Pro™ technology, an intelligent combustion regulation system. This innovation automatically optimizes the gas-air ratio, eliminating the need for manual adjustments and ensuring consistent, efficient performance within its gas family, whether operating on natural gas (G20) or convertible to liquefied petroleum gas (G31).

Operating the EcoTEC Plus 615 is straightforward thanks to its intuitive user interface. The display features color-lit control elements that are easy to select and a responsive scrollbar for adjusting values. For energy saving, the menu dims after 60 seconds, reverting to a status display. The display also clearly communicates vital information through a range of symbols, including current burner modulation, system pressure status, active heating or DHW modes, and alerts for warnings, faults, or maintenance requirements, keeping users informed at a glance.

For heating, users can directly set the desired flow temperature via the boiler's basic display or, more commonly, through an integrated sensoROOM pure (VRT 50/2) room temperature control. This external control allows for precise management of room temperature and offers advanced features like time-dependent heating with a weekly planner or a time programme assistant, optimizing comfort and energy use. When paired with an external hot water cylinder, the boiler efficiently manages DHW production. Comfort mode can be activated to keep the cylinder water readily available, minimizing waiting times for hot water.

The EcoTEC Plus 615 is equipped with robust safety features, including overheating protection that triggers a shutdown before critical temperatures are reached, safeguarding the appliance. A crucial built-in frost protection mechanism automatically activates the heating pump at 12°C and the burner at 5°C, preventing freezing within the boiler. Furthermore, the boiler intelligently ceases operation if a condensate drain blockage is detected, protecting the system from damage. Regular annual maintenance, performed by a competent person, is essential for ensuring long-term safe and efficient operation.

Beyond its core functions, the EcoTEC Plus 615 offers modern connectivity options. Users can leverage the myVAILLANT pro app to scan a QR service code on the boiler, gaining instant access to detailed product status information, including fault history, active operating modes, and system data. The boiler also tracks approximate energy consumption values for heating and, if applicable, DHW generation, providing insights into operational efficiency. This blend of performance and smart monitoring capabilities empowers users and technicians with valuable diagnostic information.

Vaillant stands by the quality of the EcoTEC Plus 615 with a two-year parts and labour guarantee, extendable with annual servicing. The product’s adherence to industry standards is underlined by its CE and UKCA markings, as well as membership in the Hot Water Association and the Benchmark Scheme. These affiliations ensure that the boiler meets stringent performance, safety, and installation criteria, promising peace of mind. Comprehensive customer service and support are readily available, ensuring reliable assistance throughout the product's lifespan.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Vaillant EcoTEC Plus 615 Boiler, and we answer them below.


What type of boiler is the Vaillant EcoTEC Plus 615?
The Vaillant EcoTEC Plus 615 is a highly efficient condensing system boiler, designed for central heating. It requires a separate hot water cylinder for domestic hot water supply.

How do I adjust the heating temperature on my EcoTEC Plus 615?
You can set the desired flow temperature directly from the boiler's basic display. If a Vaillant sensoROOM pure (VRT 50/2) room control is connected, you can set the desired room temperature there instead.

Does the boiler have a 'summer mode' to turn off heating?
Yes, you can permanently switch off heating mode from the basic display by pressing and holding the designated button for at least three seconds. If you have a sensoROOM pure (VRT 50/2) control, you can adjust the target room temperature to its lowest setting to effectively switch off heating.

What is 'Comfort Mode' for domestic hot water?
Comfort Mode (if an external hot water cylinder is connected and active) keeps the domestic hot water generation ready, supplying hot water at the desired temperature without a wait time. It is typically activated at the factory.

Is there any frost protection built into the boiler?
Yes, the EcoTEC Plus 615 has a built-in frost protection device. With gas and electricity supplies on, it will activate the pump when the boiler water temperature drops below 12°C and the burner if it falls to 5°C, preventing the boiler from freezing.

How will I know if my boiler needs maintenance?
A symbol will appear on the boiler's display indicating that maintenance work is required. You should consult a competent person (installer or service engineer) when this message appears.

What should I do if I suspect a gas leak?
If you smell gas, immediately avoid the room, open windows and doors, do not use naked flames or electrical switches, close the emergency control valve or main isolator, warn other occupants, leave the building, and alert emergency services from outside.

How often should the EcoTEC Plus 615 boiler be serviced?
An annual inspection and maintenance by a competent person is recommended to ensure the product remains safe, efficient, and reliable. This annual service is also a requirement for the validity of the second year of the two-year guarantee.

What is the recommended pressure for my heating system?
Vaillant recommends a filling pressure of at least 1 bar (0.1 MPa) for the heating system. If the pressure falls below 0.8 bar (0.08 MPa), you should top up the heating water.

What should I do if the condensate discharge pipe is blocked?
The boiler will stop working as a safety feature if the condensate drain is blocked. This can be due to ice in external pipes. Apply warm cloths to thaw ice, then press the reset button. If the blockage persists, contact a competent person.

Can I monitor my boiler's performance on my phone?
Yes, you can use the free Vaillant myVAILLANT pro app. By scanning a QR service code on the boiler's display, you can access product status information, including fault history, operating modes, and system data.