Aprilaire 500M Humidifier Instruction Manual
Aprilaire 500M Humidifier
Aprilaire 500M Humidifier
Aprilaire 500M Humidifier Instructions
Here we offer the Aprilaire 500M Humidifier manual completely free and in English. We have cataloged this manual in the Humidifiers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Aprilaire 500M Humidifier, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.
Product Images
Aprilaire 500M Humidifier Specifications
| Feature | Specification |
|---|---|
| Model | Aprilaire 500M Small Bypass Humidifier |
| Humidifier Type | Evaporative, bypass, flow-through with drain |
| Humidifier Control | Manual Humidifier Control (included) |
| Width (including solenoid valve) | 15 5/8 in. |
| Height (including drain spud) | 13 in. |
| Depth | 10 1/4 in. |
| Plenum Opening | 9 1/2 in. W x 9 1/2 in. H |
| Bypass Duct Opening | 6 in. diameter |
| Water Feed Rate | 3 gph |
| Electrical Data | 24 VAC, 60 Hz, 0.5 A |
| Transformer | 24 VAC transformer included; must not be wired into the furnace blower circuit |
| Accessory Terminal Transformer Rating | 10 VA minimum |
| Replacement Water Panel | Aprilaire Water Panel 10 |
| Water Panel Replacement Interval | At least once a year |
| Supply Water Types | Hot, cold, hard or mechanically softened |
| Maximum Hot Water Temperature | 140°F (60°C) |
| Maximum Water Pressure | 125 psi |
| Maximum Plenum Pressure Differential | 0.4 in. wg between supply and return plenums |
| Water Supply Line | 1/4 in. copper tubing (not included) |
| Drain Line | 1/2 in. I.D. hose (not included) |
| Mounting Location | Supply or return plenum; upflow or horizontal systems |
| Bypass Connection | Left side by default, can be switched to the right |
| Bypass Damper | Built-in, WINTER/SUMMER positions |
| In-Line Strainer Part Number | 4004 |
| Orifice Part Numbers | 4231 (yellow) or 4232 (blue), depending on model |
| Housing Materials | Parts that touch water are non-metal and do not rust or corrode |
| Warranty | 5 years limited, from date of purchase |
| Technical Support | 800.334.6011 |
Aprilaire 500M Humidifier Details
The Aprilaire 500M is an evaporative bypass humidifier. It uses heat from the HVAC system to turn water into vapor. When the control calls for humidity and the system fan is running, water flows into a distribution tray. The tray spreads the water evenly over the Water Panel, and warm, dry air from the supply duct passes through the wet panel and returns to the return duct carrying moisture.
The unit uses a flow-through drain design. A small, steady stream of water runs to the drain, which flushes away most of the minerals that cause problems and prevents stagnant water. An orifice supplied with the humidifier keeps the water flow correct. The saddle valve should only ever be fully open or fully closed and must never be used to adjust the flow.
The included Manual Humidifier Control can be mounted in the cold air return duct or on an inside wall. For duct mounting, place it at least 6 in. upstream of the humidifier or bypass connection. For wall mounting, pick a spot away from drafts and heat sources. To estimate the indoor RH, turn the knob slowly back and forth and listen for two clicks. The current humidity is within that range.
Because the control does not adjust itself, the owner should lower the set point before outdoor temperatures drop to avoid condensation. Recommended settings are 45% RH at +40°F, 35% at +20°F, 25% at 0°F and 15% at -20°F. Fog or frost on the inside of windows usually means the humidity is too high.
The humidifier is designed for one-person servicing. Release the top and bottom tabs to remove the front cover, pull the feed tube out of the tray, and tip out the evaporative assembly. Unsnap the distribution tray, then gently scrape or brush mineral deposits from it without stretching the fabric liner. Vinegar or a lime-removing agent helps loosen stubborn scale.
Slide the new Water Panel 10 into the scale control insert with the colored spot facing up. Fit the assembly's drain into the round receptacle at the base and press it in until it snaps into place. Check the feed tube for cracks, flush the drain line under pressure, and make sure the drain line slopes steadily downward.
Once a year, also clean the in-line strainer, check that the orifice opening is clear, and check the solenoid valve connections. Use two wrenches when tightening any compression nut. At the end of the heating season, turn the bypass damper handle from WINTER to SUMMER and set the control knob to OFF.
The installation must be done by a qualified HVAC contractor, or the warranty is void. Do not mount the humidifier on the furnace jacket, in a space where it could freeze, or where the blanked-off ends of a cooling coil block airflow. On heat pump systems, use hot water to make up for the lower supply air temperature.
The warranty does not cover consumables such as Water Panels, labor charges, improper installation, or normal wear. Register the product at aprilaire.com/warranty to make any future claim easier.
Frequently Asked Questions (FAQs)
Can't find the answer you need? Here are some frequently asked questions about the Aprilaire 500M Humidifier, and we answer them below.