WaterBoss 700 Water Softener Instruction Manual

Manual WaterBoss 700 Water Softener Instruction Manual

WaterBoss 700 Water Softener Instruction Manual

5/5 (1👤)
📕 Manual PDF 📄 31 Pages
★Rate It★

How many stars do you give this manual?

WaterBoss 700 Water Softener

Full Screen

WaterBoss 700 Water Softener Instructions

Here we offer the WaterBoss 700 Water Softener manual completely free and in English. We have cataloged this manual in the Water Softeners section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about WaterBoss 700 Water Softener, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5

WaterBoss 700 Water Softener Specifications

Specification Value
Maximum Compensated Hardness 70 gpg (1,200 mg/L)
Maximum Ferrous Iron Reduction 10 ppm
Minimum pH 7 standard units
Media Type and Amounts Self-Cleaning Filter Media Super Fine Mesh Resin Total—0.7 cu. ft. (20L)
Salt Dosage (Low Efficiency) 1.1 lbs (kg)
Capacity (Low Efficiency) 5105 grains
Water Usage (Low Efficiency) 19.4 gal (73.4 L)
Regeneration Time (Low Efficiency) 20:30 minutes
Salt Dosage (Medium Efficiency) 6.5 lbs (2.9 kg)
Capacity (Medium Efficiency) 15640 grains
Water Usage (Medium Efficiency) 30.7 gal (116.2 L)
Regeneration Time (Medium Efficiency) 34:00 minutes
Salt Dosage (High Capacity) 12 lbs (5.4 kg)
Capacity (High Capacity) 18759 grains
Water Usage (High Capacity) 36.2 gal (137.1 L)
Regeneration Time (High Capacity) 43:00 minutes
Minimum / Maximum Water and Ambient Temperature 40°F - 100°F (4°C - 38°C)
Mineral Tank Size (I.D. x H) 10.5 I.D. x 19 in. (26.7 I.D. x 48.3 cm)
Service Flow Rate 8 gpm (30 L/Min)
Pressure Drop at Service Flow Rate (8 gpm) 15 psi (1.0 bar)
Maximum Flow Rate to Drain During Regeneration (Backwash) 2.0 gpm (7.6 L/min)
Water Pressure (Min-Max) 20-80 psi (1.4-5.5 bar)
Minimum Water Flow Required 2.0 gpm (7.6 L/min)
Maximum Chlorine 0.0 ppm
Controller Type 4 Button Demand
Frequency of Regeneration Demand
Salt Storage Capacity 100 lbs (45 kg)
Height 25.5 in. (65 cm)
Footprint 15 X 19 in. (38 X 48 cm)
Electrical Rating 12 VAC, 50/60 Hz, 0.015 kW-hr
Plumbing Connections 1” male (MNPT)
Shipping Weight (Approximate) 85 lbs (39 kg)
Rated Efficiency (at 1.1 lbs salt) 4641 grains/lb
Capacity at 1.1 lbs salt dosage 5105 grains

WaterBoss 700 Water Softener Details

The WaterBoss 700 water softener delivers a superior water treatment solution, designed for efficiency and user convenience. It features a robust four-button controller with an intuitive LCD display. Operating primarily in Demand Mode, the system intelligently measures water usage and initiates regeneration only when necessary, eliminating the need for vacation settings or adjustments for varying guest loads. This smart approach ensures optimal salt and water conservation. During regeneration, the display shows specific cycle numbers, and once complete, it indicates the remaining soft water capacity in hundreds of gallons, with the entire process typically finishing in about 30 minutes.

Further enhancing its user-friendliness, the WaterBoss 700 includes a waterMizer® indicator that illuminates whenever water flows through the appliance, aiding in plumbing checks and leak detection. For households dealing with excessive iron, the powerClean™ feature is a valuable asset. This specialized service/maintenance step triggers regeneration every other day using five pounds of salt, effectively combating iron buildup in the resin bed. It is recommended for a minimum of two weeks and can be supported by an iron cleaning agent for continuous preventive care. The unit retains all programmed settings indefinitely, even after power outages, ensuring consistent performance.

Maintaining the WaterBoss 700 is straightforward, focusing on proper salt management. Users should keep the salt level at least one-third full, refilling when it drops below the water line in the brine cabinet. The manual specifically recommends clean white pellet, cube-style, or solar salt, cautioning against rock salt or mixing different salt types. While potassium chloride can be used as a substitute, it is not recommended if the water contains iron or manganese. Regular checks after power outages to reset the time are advised. For comprehensive sanitation, the appliance can be disinfected by adding 4.0 fluid ounces of household chlorine bleach to the brine well and initiating a manual regeneration.

Proper installation is crucial for the WaterBoss 700's optimal performance. It must be installed before the water heater and after the pressure tank in well-water systems. Critical requirements include a minimum pH of 7 and protection against freezing temperatures for both the appliance and its drain line. The manual emphasizes providing an adequate air gap or siphon break for the drain to comply with plumbing codes. A bypass valve is integrated, allowing users to isolate the softener for maintenance or to access untreated water for outdoor uses like watering plants. Adherence to all operational, maintenance, and placement requirements outlined in the manual is essential for maximizing benefits.

The controller offers advanced settings for customization. Users can choose between High Capacity (HC), which means less frequent regenerations but more salt usage, or the default High Efficiency (HE) mode. HE regenerates more often, uses less salt, and meets stringent state requirements for salt efficiency (4,000 grains per pound or better). For water supplies with iron, activating the "96 Hours Until Regeneration" option ensures the appliance regenerates at least every four days, preventing iron fouling. Other customizable options include setting the display for gallons or liters, choosing a 12-hour or 24-hour clock, and defining the specific time for regeneration cycles, typically set for periods of low water usage like 2 AM.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the WaterBoss 700 Water Softener, and we answer them below.


Why is there no soft water after regenerations?
Check for low salt levels in the brine cabinet, plugged brine lines/air check/draw tube assembly, clogged flow control, or a pinched/frozen drain line. Also, a "salt bridge" might have formed, preventing salt from dissolving properly.

Why is the water still hard, even without recent regenerations?
Ensure the bypass valve is in the "Service" position, not "Bypass." Verify the appliance is plumbed correctly (not backward). Check if the water hardness has increased, requiring a re-entry of the setting number. Also, confirm the waterMizer® indicator shows flow when water is used, indicating proper metering.

What should I do if the controller display is blank?
First, check if the transformer is plugged in and the outlet has power and isn't controlled by a switch. If power is present, the transformer or circuit board might be defective. High ambient room temperatures (above 120°F/49°C) can also cause the display to blank, but this does not affect operation.

Why does the appliance stay in regeneration mode?
This could be due to the controller not being attached properly, a defective magnet disk, a foreign object in the main control valve, or a broken valve assembly (if the motor is running). Ensure the controller is fully seated onto the drive end cap.

What causes excessive water in the brine cabinet?
This is usually caused by a restricted, frozen, or pinched drain line; a plugged brine line, flow control, or air check/draw tube; a plugged injector assembly; or a sticking brine refill valve. Inspect and clean these components as necessary.

Why is my water salty after regeneration?
Salty water can result from a plugged injector (check screen, nozzle, throat), low water pressure (ensure >20 psi), a restricted drain line/flow control, or a crimped/restricted brine line. Excessive water in the brine cabinet or a dripping brine valve can also be culprits.

What do the error messages on the controller mean?
"E1" (Home not found) means to cycle power and ensure the controller is fully attached. "E2" (Motor error) suggests motor wiring or plug issues; cycle power. "E3" (Home offset) indicates the disk didn't start in the proper location, the controller tries to reset. "E4" (Home latched) means gear teeth aren't engaged, stripped, or jammed; cycle power. "E5" (Memory Error) requires controller replacement.

Can I use potassium chloride instead of salt?
Yes, you may switch to potassium chloride, but if you do, increase your hardness setting by 12% (multiply by 1.12). Caution: Do not use potassium chloride if your water contains iron and/or manganese.

How often should I clean the brine cabinet?
Inspect and clean the brine cabinet and air check/draw tube assembly annually or whenever sediment is present.

How do I disinfect the appliance?
Add 4.0 fluid ounces of 5.25% sodium hypochlorite (household chlorine bleach) to the brine well of the brine cabinet, ensuring water is present. Then, start a manual regeneration.

What is the powerClean™ feature for?
The powerClean™ feature is a service/maintenance step for water supplies with excessive iron. When activated, the appliance regenerates every other day with five pounds of salt to eliminate iron buildup in the resin bed. It's recommended to leave it on for at least two weeks and to use an iron cleaning agent.

Can I install the WaterBoss 700 outdoors?
For outside installations, the appliance should be enclosed to protect it from the weather.

Related product manuals

Go up