Here we offer the Intermatic Timer T101 Digital Timer manual completely free and in English. We have cataloged this manual in the Digital Timers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Intermatic Timer T101 Digital Timer, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5

Intermatic T101 Digital Timer Specifications

Specification Value
Model T101 24 Hour Dial Time Switch
Type Type 1 Indoor Use Only, Single Pole Single Throw (SPST)
Voltage Rating 120/208/240 VAC
Frequency 60 Hz (for clock motor)
Resistive / Inductive / Tungsten Load 40 A @ 120/208/240 VAC
Pilot Duty 1000 VA @ 120/208/240 VAC
Motor HP (120 VAC) 2 HP (24 FLA)
Motor HP (240 VAC) 5 HP (28 FLA)
Electronic Ballast 16 A @ 277 VAC
Clock Motor Voltage 120 VAC
Minimum Wire Insulation Temperature 90°C
Conductor Type COPPER conductors ONLY
Terminal Screw Torque 2-18 in-lbs
Min. Copper Wire Size (AWG) / Max. Load 14 AWG / 15A
12 AWG / 20A
10 AWG / 30A
8 AWG / 40A
Motor HP by Wire Size (120V / 240V) 14 AWG: 1/2 HP / 2 HP
12 AWG: 1 HP / 2 1/2 HP
10 AWG: 2 HP / 3 HP
8 AWG: N/A / 5 HP

Intermatic Timer T101 Digital Timer Details

The Intermatic Timer T101 is a robust 24-hour dial time switch designed for precise scheduling of electrical loads. Classified as a Type 1 device for indoor use only, it features a Single Pole Single Throw (SPST) configuration, making it suitable for a wide range of applications requiring timed on/off operations, from lighting to general-purpose appliances.

Programming the T101 is straightforward using its unique tripper system. Users simply hold the trippers against the edge of the clock dial, aligning them with the desired ON and OFF times (AM or PM). Once positioned, the tripper screws must be tightened firmly. For applications requiring more than one ON/OFF cycle per day, additional tripper pairs (part number 156T1978A) can be ordered and installed.

Setting the current time-of-day is equally intuitive. To adjust, gently pull the CLOCK-DIAL outward, then rotate it in either direction. The goal is to align the exact current time-of-day on the dial with the fixed time pointer. It's crucial to never move the pointer itself, as this can damage the timer's internal mechanism and affect its accuracy.

Manual operation is available for overriding programmed schedules without affecting subsequent operations. A convenient MANUAL LEVER located below the clock dial allows users to move the switch left or right, as indicated by arrows, to instantly turn the connected load ON or OFF. In the event of a power failure, the timer retains its programming but the clock-dial must be manually reset to the correct time-of-day to maintain accurate scheduling.

Installation safety is paramount. Before any wiring or servicing, it is essential to disconnect power at the circuit breaker or disconnect switches. All wiring and installation procedures must strictly adhere to national and local electrical code requirements. The timer is designed exclusively for COPPER conductors with a minimum insulation rating of 90°C. Wire ends should have 1/2 inch of insulation removed, and terminal screws must be tightened firmly between 2-18 in-lbs to ensure secure connections.

Beyond its general timing capabilities, the T101 also serves as a specialized control device for swimming pool pumps and heaters. This particular feature incorporates a "Fireman" switch, whose contacts are typically closed at all times, except for a 20-minute period before the pump is scheduled to turn OFF. This clever design prevents the heater from operating during the final circulation phase, promoting efficiency and safety.

The heater control is specifically engineered to allow the water to circulate for 20 minutes without heat, ensuring proper cooling. Furthermore, it enables a remote override function, allowing users to operate both the pump and the heater simultaneously from an external location without manually engaging the timer. This provides significant operational flexibility for pool owners.

For those utilizing the T101 (or T104) as the sole control for a pool pump and heater, an additional 156T4042A Heater Control Switch Kit can be installed on the time switch plate. This accessory ensures that the heater only operates when the Time Switch contacts are closed, either automatically via programming or manually. It's an important consideration for integrated pool system management.

It is critical to note that this specific type of heater control functionality should not be used as a substitute for a pressure or flow switch within the heater control circuit. These safety devices serve different, vital functions in heater protection. Always ensure your setup complies with all safety standards and local regulations.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Intermatic Timer T101 Digital Timer, and we answer them below.


What is the primary function of the Intermatic T101 Digital Timer?
The Intermatic T101 is a 24-hour dial time switch designed for automatically turning electrical loads ON and OFF at preset times, operating on a daily cycle.

What electrical loads can the T101 handle?
It can handle resistive, inductive, and tungsten loads up to 40A at 120/208/240 VAC, pilot duty up to 1000 VA, motor loads up to 5 HP (240 VAC), and electronic ballast loads up to 16A at 277 VAC.

How do I set the ON/OFF times on the timer?
To set ON/OFF times, you use the trippers provided. Hold them against the edge of the CLOCK-DIAL, pointing to the desired ON/OFF times, and then tighten the tripper screws firmly.

What should I do if I need more ON/OFF cycles than the included trippers allow?
Additional tripper pairs can be purchased. The part number for additional trippers is 156T1978A.

How do I set the current time-of-day on the T101?
Pull the CLOCK-DIAL outward and rotate it in either direction to align the current time-of-day with the time pointer. It is crucial NOT to move the pointer itself.

Can I manually operate the switch if needed?
Yes, you can manually operate the switch by moving the MANUAL LEVER below the CLOCK-DIAL left or right. This will not affect the next scheduled automatic operation.

What happens to the timer during a power outage?
In case of a power failure, the timer's internal clock will stop. You will need to manually reset the CLOCK-DIAL to the proper time-of-day once power is restored to ensure accurate scheduling.

Are there any specific wiring requirements for installation?
Yes, use only COPPER conductors rated at least 90°C. Wires should have 1/2 inch of insulation removed, and terminal screws must be tightened firmly between 2-18 in-lbs.

What safety precautions should be followed during installation?
Always disconnect power at the circuit breaker(s) before installing or servicing. Ensure installation and wiring comply with national and local electrical codes, and replace the plastic insulator covering terminals before powering on.

Can this timer be used outdoors?
No, the Intermatic T101 is explicitly designated as a Type 1 device, meaning it is for INDOOR USE ONLY.

What is the 'Fireman' switch feature for swimming pool heaters?
This feature allows the heater control contacts to be closed at all times except for 20 minutes before the pool pump is scheduled to turn OFF. This prevents the heater from operating during the final circulation period.

How does the 'Fireman' switch protect my pool heater?
It ensures that water circulates for 20 minutes without heat before the pump turns off, helping to cool down the heater and prevent potential damage from overheating when flow ceases.

Can the pool heater be operated remotely with this timer?
Yes, the control is designed to allow override from a remote location to operate both the pump and the heater without manually turning on the timer.

Is the T101's heater control a replacement for a pressure or flow switch?
No, the manual explicitly states that this type of control should not be used in lieu of a pressure or flow switch in the heater control circuit, as those are vital safety devices.

What if the clock motor needs replacement?
The clock motor voltage and cycle must match the specified ratings (120 VAC, 60 HZ). To order a replacement, indicate the part number (WG--) found on the motor cover.