Osburn Matrix 2700 Chimney Instruction Manual

Manual Osburn Matrix 2700 Chimney Instruction Manual

Osburn Matrix 2700 Chimney Instruction Manual

5/5 (1👤)
📕 Manual PDF 📄 62 Pages
★Rate It★

How many stars do you give this manual?

Osburn Matrix 2700 Chimney

Full Screen

Osburn Matrix 2700 Chimney Instructions

Here we offer the Osburn Matrix 2700 Chimney manual completely free and in English. We have cataloged this manual in the Chimneys section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Osburn Matrix 2700 Chimney, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5

Osburn Matrix 2700 Chimney Specifications

Feature Specification
Model Matrix 2700 Insert (OB02700)
Combustion Technology Non-catalytic
Fuel Type Dry Cordwood
Recommended Heating Area 750 to 2,200 sq. ft. (70 to 204 m²)
Overall Firebox Volume 2.5 ft³ (0.071 m³)
EPA Loading Volume 1.94 ft³ (0.055 m³)
Maximum Burn Time 8 hours
Maximum Heat Output (dry cordwood) 80,000 BTU/h (23.4 kW)
Overall Heat Output Rate (min. to max.) 12,700 BTU/h to 60,700 BTU/h (3.72 kW to 17.79 kW)
Average Overall Efficiency (Dry cordwood) 64% (HHV) / 68% (LHV)
Optimum Overall Efficiency 70%
Optimum Heat Transfer Efficiency 68%
Average Particulate Emissions Rate 1.2 g/h (EPA / CSA B415.1-10)
Average CO 98 g/h
Recommended Log Length 16 in (406 mm) east-west
Maximum Log Length 20 in (508 mm) east-west
Flue Outlet Diameter 6 in (150 mm)
Recommended Connector Pipe Diameter 6 in (150 mm)
Type of Chimney ULC S635, CAN/ULC-S640, UL 1777
Baffle Material C-Cast or equivalent
Approved for Alcove Installation Not applicable
Approved for Mobile Home Installation No
Type of Door Simple, glass with cast iron frame
Type of Glass Ceramic glass (5/32" or 4mm thick)
Blower Included (up to 176 CFM)
Particulate Emission Standard EPA / CSA B415.1-10
USA Safety Standard UL 1482, UL 737
Canada Safety Standard ULC-S628

Osburn Matrix 2700 Chimney Details

The Osburn Matrix 2700 Insert is a highly certified wood-burning appliance, meeting stringent safety standards including ULC S628, UL 1482, and UL 737. It is also a US Environmental Protection Agency (EPA) Phase II certified wood insert, compliant with the 2020 cord wood standard, reflecting its commitment to reduced emissions.

Manufactured by Stove Builder International (SBI), a reputable North American company, this insert is designed for quality and performance. Installation by NFI, CSIA (USA), or WETT, APC (Canada/Quebec) certified professionals is strongly recommended to ensure safety and compliance with local building codes, which may include obtaining permits.

The unit features a robust construction, primarily from recyclable carbon steel, with stainless steel air tubes and a C-Cast baffle. Its low VOC paint minimizes environmental impact during manufacturing. The ceramic glass door is 5/32" thick, designed to withstand high temperatures, though it cannot be recycled with standard household glass.

Designed for 'zone heating,' the Matrix 2700 efficiently warms the area it's installed in and adjacent spaces. This method allows homeowners to maintain comfortable temperatures in active areas while potentially keeping other rooms cooler, thus optimizing wood consumption. It's important to remember this unit is intended as a supplementary heat source, with a primary alternative available.

This wood insert is engineered for high efficiency, achieving complete wood combustion that releases maximum heat energy while producing significantly less smoke compared to older models. Achieving optimal efficiency and low emissions largely depends on using dry, seasoned firewood with a moisture content between 15% and 20%.

The manual strictly prohibits burning various materials, including garbage, plastics, treated wood, and accelerants, as these can release toxic fumes or damage the unit. Proper fuel preparation, including splitting logs to various sizes, is emphasized for quicker drying and ignition. Dry wood can be identified by cracks, color changes, a hollow sound, and reduced weight.

Operating the insert involves specific lighting methods to establish a hot fire quickly, minimizing smoke and creosote buildup. The included blower enhances heat circulation and can be operated manually or automatically via a heat sensor. For safety, the door must be fully closed during operation, or a fire screen (sold separately) used if regulations permit open-door burning.

Regular maintenance is crucial for longevity and safe operation. This includes periodic inspection of refractory panels, baffle, and air tubes, as well as cleaning the ceramic glass. The chimney system also requires regular inspection and cleaning to prevent creosote accumulation, which can lead to dangerous chimney fires. A continuous 6-inch stainless steel liner is mandatory.

The design accommodates customizable installation options, including a 2-inch or 4-inch projection kit and various faceplate styles. Clearances to combustible materials, including mantel shelves and floor protection, are detailed to ensure safety. The chimney's height and indoor location are important for optimal draft and efficient operation, minimizing issues like cold back-drafting.

The Osburn Matrix 2700 features an adjustable air intake control, allowing users to regulate the burn rate and heat output. Understanding burning cycles and appropriate log orientation helps tailor heat delivery to specific needs, from flash fires for mild weather to long-output fires for colder conditions. These controls ensure efficient performance and user comfort.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Osburn Matrix 2700 Chimney, and we answer them below.


What certifications does the Osburn Matrix 2700 Insert hold?
The Osburn Matrix 2700 is safety tested according to ULC S628, UL 1482, and UL 737. It is also a US EPA Phase II certified wood insert compliant with the 2020 cord wood standard.

Can I install this insert in a mobile home or alcove?
No, the Osburn Matrix 2700 Insert is not approved for installation in mobile homes or alcoves. The manual explicitly states 'Not applicable' for alcove installation and 'No' for mobile home installation.

What type of chimney liner is required for installation?
A continuous 6-inch (150 mm) diameter stainless steel chimney liner, listed UL 1777, ULC S635, or CAN/ULC S640, extending from the insert to the top of the chimney, is required.

Is professional installation recommended for this wood insert?
Yes, it is highly recommended that this wood burning hearth product be installed and serviced by professionals certified by NFI (National Fireplace Institute®) or CSIA (Chimney Safety Institute of America) in the United States, or by WETT (Wood Energy Technology Transfer) or APC (Association des Professionnels du Chauffage) in Canada.

What kind of fuel should I burn in the Osburn Matrix 2700?
Only dry, seasoned natural firewood with a moisture content between 15% and 20% should be burned. Prohibited materials include garbage, plastics, treated wood, gasoline, kerosene, or similar liquids.

How often should I clean the chimney?
You should inspect the chimney monthly to determine the rate of creosote formation. Even if creosote forms slowly, the chimney should be cleaned and inspected at least once each year.

Can I operate the insert with the door open?
The insert has been tested for open-door use *only* with a rigid fire screen, sold separately. However, in regions with particulate emissions limits (like US EPA), open-door use with a fire screen is prohibited. Always close the door or use the fire screen after ignition and never leave the insert unattended when the door is open.

How do I know if my firewood is dry enough?
Dry wood will show cracks at the ends, turn from white/cream to grey/yellow, sound hollow when two pieces are struck together, be lighter than wet wood, feel warm and dry when freshly cut, and have a moisture content between 15% to 20% when checked with a moisture meter.

What should I do if a chimney fire occurs?
Immediately close the insert door and the air intake control. Alert all occupants, call the fire department if necessary, and use a dry chemical fire extinguisher, baking soda, or sand to control the fire if possible. *Never use water.* Do not use the appliance again until it and the chimney have been inspected by a qualified professional.

How does the included blower operate?
The blower has a variable speed control (HI/LO/OFF) and is equipped with a heat sensor. It can be set to start automatically when the insert is hot enough (Auto position), run continuously manually, or remain off.

What is 'zone heating' and how does it apply to this insert?
Zone heating uses the insert as a space heater to efficiently warm the area where it's installed, along with connected spaces, typically the main living area. This allows for comfortable temperatures where most time is spent, while other areas like bedrooms remain cooler, reducing overall wood consumption.

Related product manuals

Go up