Here we offer the Aprilaire 700M Humidifier manual completely free and in English. We have cataloged this manual in the Humidifiers section on Manualverse, and it has been rated by 1 users with an average rating of 5. If you have any specific questions about Aprilaire 700M Humidifier, we suggest checking the Frequently Asked Questions (FAQs) section of this manual.


Product Images

Imagen 1
Imagen 2
Imagen 3
Imagen 4
Imagen 5
Miniatura 1
Miniatura 2
Miniatura 3
Miniatura 4
Miniatura 5

Aprilaire 700M Humidifier Specifications

Feature Specification
Model Aprilaire 700M Large Fan Powered Humidifier
Humidifier Type Whole-house evaporative, fan-powered (built-in fan)
Humidifier Control Manual Humidifier Control (included)
Control Mounting Cold air return duct or interior wall of the living space
Width 15-29/32 in
Height (including solenoid valve and drain spud) 18 in
Depth 10-11/32 in
Plenum Opening 14-3/4 in W x 14-5/16 in H
Mounting Location Warm air supply plenum (not on furnace jacket)
Water Feed Rate 6 gph
Electrical Data 120 VAC, 60 Hz, 0.8 A
Control Circuit 24 VAC (transformer included, 10 VA minimum)
Maximum Water Pressure 125 psi
Maximum Supply Plenum Static Pressure 0.4 in wg
Supply Water Hot, cold, hard or softened; hot water up to 140°F (60°C) recommended
Replacement Water Panel AprilAire Water Panel 35
Water Panel Replacement Interval At least once a year
Water Supply Line 1/4 in copper tubing (not furnished)
Drain Line 1/2 in I.D. hose to floor drain (not furnished)
Drain System Flow-through with continuous drain flushing
In-line Strainer Part No. 4004
Orifice Part No. 4231 (yellow) or 4232 (blue), depending on model
Motor Permanently lubricated, no oiling needed
Furnished Items 24 VAC transformer, Manual Humidifier Control, saddle valve, installation template, control instructions
Limited Warranty 5 years from date of purchase
Technical Support 800.334.6011

Aprilaire 700M Humidifier Details

The Aprilaire 700M is a large fan-powered evaporative humidifier. It adds moisture to the warm, dry air from your heating system. Unlike bypass models, it has a built-in fan that pulls air through the Water Panel, so it does not need a bypass duct to the return. The humidifier does not heat the water. It uses heat from the furnace to evaporate the water, and the humidified air then travels through the home's ductwork.

When the control calls for humidity and the HVAC fan is running, water flows into a distribution tray with a synthetic fabric liner. The tray spreads water evenly over the top of the Water Panel through "V" openings, but only if the unit is mounted level. A scale control insert surrounds the panel and traps mineral deposits. A small, steady stream of water runs to the drain and flushes away most minerals. This also prevents problems from standing water.

All housing parts that touch water are non-metal, so they will not rust or corrode. An orifice sets the correct water flow. Do not use the saddle valve to adjust flow, because it is designed to be fully open or fully closed. Keep the humidifier out of any area where water could freeze. Do not install it where the blanked-off end of a cooling coil blocks airflow, or on ducts with horizontal airflow, because performance will drop.

The Manual Humidifier Control needs you to make seasonal adjustments. When outdoor temperatures are about to drop, lower the set point to prevent condensation. The manual suggests 45% RH at 40°F, 35% at 20°F, 25% at 0°F and 15% at -20°F. To estimate the current indoor RH, turn the knob slowly back and forth and listen for two clicks. The indoor humidity falls between those two points.

For wiring, do not connect the power cord to multispeed furnace blower motors or to motors other than 120 VAC. In those cases, use a Model 50 Current Sensing Relay wired into the 24 VAC control circuit. Do not wire the transformer into the furnace blower circuit. On downflow furnaces, the blower must keep running after a heat call ends so the control is not exposed to high heat. On heat pump systems, use hot water to make up for the cooler supply air.

Plan on yearly maintenance. Disconnect power and water, unlatch the cover, and tip out the evaporator assembly. Clean the distribution tray, soaking it in vinegar if deposits are stubborn. Install a new Water Panel 35 with the colored spot facing up. Inspect the feed tube, and flush the drain line under pressure. The drain line must slope downward the whole way. The in-line strainer and orifice also need regular inspection.

For summer, set the Manual Humidifier Control to OFF. Since the 700M has no bypass damper, no damper adjustment is needed. Indoor activities such as cooking, showering and drying clothes can push humidity too high even when the humidifier is off. If condensation stays on windows for several hours, ventilate the home. Keep fireplace dampers closed when not in use.

Frequently Asked Questions (FAQs)

Can't find the answer you need? Here are some frequently asked questions about the Aprilaire 700M Humidifier, and we answer them below.


Which Water Panel does the Aprilaire 700M use?
The 700M uses the genuine AprilAire Water Panel 35. Replace it at least once a year for best performance.

What is the difference between the 700M and the 700?
The 700M comes with a Manual Humidifier Control that you adjust by hand as outdoor temperatures change. The 700 uses an Automatic Digital Humidifier Control with an outdoor temperature sensor, indicator lights and Blower Activation.

Can I use cold water with the 700M?
Yes. It works with hot, cold, hard or softened water. Hot water up to 140°F (60°C) gives the most evaporation and is required on heat pump systems.

What are the electrical requirements?
The humidifier needs 120 VAC, 60 Hz and draws 0.8 A. The control runs on 24 VAC from the included transformer, which must not be wired into the furnace blower circuit.

What size opening is needed in the plenum?
Cut an opening 14-3/4 in wide by 14-5/16 in high in the supply plenum, using the included template. Make sure the template is level.

How much water does the 700M use?
The water feed rate is 6 gallons per hour. Part of this water drains away continuously to flush out minerals.

Where can the Manual Humidifier Control be installed?
You can mount it in the cold air return duct, or on an interior wall away from drafts and heat sources.

How do I check that the humidifier is working?
Turn on the HVAC fan with a heat or fan call. Set the control knob to its highest RH setting, and make sure the saddle valve is open and the unit has power. Once you've confirmed it works, return the knob to the setting you want.

Does the fan motor need oiling?
No. The motor is permanently lubricated and never needs oil.

What is the maximum water pressure?
Do not install the humidifier where water pressure exceeds 125 psi. Use pressure reduction where local codes require it.

What should I do for summer shutdown?
Set the Manual Humidifier Control knob to OFF. The 700M has no bypass damper, so you don't need to make any damper adjustment.

How long is the warranty?
The humidifier has a 5-year limited warranty against defects in materials or workmanship. Water Panels, labor and damage from improper installation are not covered.